Short axis versus axial Cine SSFP MR imaging for assessment of right and left ventricular function: intrapatient correlation with phase-contrast flow measurements

نویسندگان

  • Susan H James
  • Rachel Wald
  • Bernd J Wintersperger
  • Laura Jimenez-Juan
  • Djeven Deva
  • Andrew Crean
  • Elsie Nguyen
  • Narinder Paul
  • Sebastian Ley
چکیده

Background MRI is deemed standard of reference for assessment of ventricular volumes and function. However, it remains unclear if the RV can also be adequately assessed in SAO orientation as used for assessment of LV function or requires dedicated axial-Cine imaging. Additional axial-Cine acquisition adds 10-15 min of scan time and thus has a substantial impact on clinical workflow and patient comfort.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of slice orientation on reproducibility of sequential assessment of right ventricular volumes and ejection fraction: short-axis vs transverse SSFP cine cardiovascular magnetic resonance

BACKGROUND Test-retest reproducibility is of utmost importance in follow-up of right ventricular (RV) volumes and function; optimal slice orientation though is not yet known. We compared test-retest reproducibility and intra-/inter-observer variability of right ventricular (RV) volumes and function assessed with short-axis and transverse cardiovascular magnetic resonance (CMR). METHODS Eighte...

متن کامل

Evaluation of left ventricular volumes and ejection fraction using fast steady-state cine MR imaging: comparison with left ventricular angiography.

Previous studies demonstrated that magnetic resonance (MR) imaging consistently underestimated angiographic measurements of left ventricular (LV) volumes. The purpose of this study was to determine whether MR imaging with steady-state free precession acquisition (SSFP) can provide improved accuracy and reproducibility in measuring cardiac function in comparison with fast spoiled gradient echo c...

متن کامل

Unsupervised free-breathing 3-dimensional imaging of morphology, function and flow in congenital heart disease under 30 minutes: pilot study

Methods Five patients with CHD were included in this pilot study (table 2 in Figure 2). The FB MR studies were performed on a Philips Acheiva 1.5T magnet using a 5-channel phased array coil (see Table 1 in Figure 1) 1. Respiratory synchronized [1], time-resolved MRA 2. Equilibrium phase MRA 3. 3D cine SSFP 4.4D phase contrast (PC) flow imaging 5.3D whole-heart single phase SSFP (coronary) Compa...

متن کامل

How to measure the right ventricular outflow tract with cardiovascular magnetic resonance imaging: a head-to-head comparison of methods.

INTRODUCTION Structural abnormalities of the right ventricular outflow tract (RVOT) have been described in several clinical conditions. The aim of our study was to prospectively compare the available approaches to measuring the RVOT area and diameter by cardiovascular magnetic resonance imaging (CMR) and establish reference values in healthy volunteers. In addition, we sought to introduce a new...

متن کامل

Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agent

BACKGROUND Cardiovascular magnetic resonance (CMR) is the current gold standard for the assessment of left ventricular (LV) function. Repeated breath-holds are needed for standard multi-slice 2D cine steady-state free precession sequences (M2D-SSFP). Accelerated single breath-hold techniques suffer from low contrast between blood pool and myocardium. In this study an intravascular contrast agen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2011