Three-dimensional ultrasound for image-guided mapping and intervention: methods, quantitative validation, and clinical feasibility of a novel multimodality image mapping system.

نویسندگان

  • Yasuo Okumura
  • Benhur D Henz
  • Susan B Johnson
  • T Jared Bunch
  • Christine J O'Brien
  • David O Hodge
  • Andres Altman
  • Assaf Govari
  • Douglas L Packer
چکیده

BACKGROUND Multiple factors create discrepancies between electroanatomic maps and merged, preacquired computed tomographic images used in guiding atrial fibrillation ablation. Therefore, a Carto-based 3D ultrasound image system (Biosense Webster Inc) was validated in an animal model and tested in 15 atrial fibrillation patients. METHODS AND RESULTS Twelve dogs underwent evaluation using a newly developed Carto-based 3D ultrasound system. After fiducial clip markers were percutaneously implanted at critical locations in each cardiac chamber, 3D ultrasound geometries, derived from a family of 2D intracardiac echocardiographic images, were constructed. Point-source error of 3D ultrasound-derived geometries, assessed by actual real-time 2D intracardiac echocardiographic clip sites, was 2.1+/-1.1 mm for atrial and 2.4+/-1.2 mm for ventricular sites. These errors were significantly less than the variance on CartoMerge computed tomographic images (atria: 3.3+/-1.6 mm; ventricles: 4.8+/-2.0 mm; P<0.001 for both). Target ablation at each clip, guided only by 3D ultrasound-derived geometry, resulted in lesions within 1.1+/-1.1 mm of the actual clips. Pulmonary vein ablation guided by 3D ultrasound-derived geometry resulted in circumferential ablative lesions. Mapping in 15 patients produced modestly smaller 3D ultrasound versus electroanatomic map left atrial volumes (98+/-24 cm(3) versus 109+/-25 cm(3), P<0.05). Three-dimensional ultrasound-guided pulmonary vein isolation and linear ablation in these patients were successfully performed with confirmation of pulmonary vein entrance/exit block. CONCLUSIONS These data demonstrate that 3D ultrasound images seamlessly yield anatomically accurate chamber geometries. Image volumes from the ultrasound system are more accurate than possible with CartoMerge computed tomographic imaging. This clinical study also demonstrates the initial feasibility of this guidance system for ablation in patients with atrial fibrillation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Subsampling Method for 3D Multimodality Medical Image Registration Based on Mutual Information

Mutual information (MI) is a widely used similarity metric for multimodality image registration. However, it involves an extremely high computational time especially when it is applied to volume images. Moreover, its robustness is affected by existence of local maxima. The multi-resolution pyramid approaches have been proposed to speed up the registration process and increase the accuracy of th...

متن کامل

Integration of Remote Sensing and the GIS-based Methods for Provision of Cadastral Mapping of Agricultural Areas of Ardakan City

In the fifth development plan establishment, establishment of the Cadastre System of agriculture nationwide has been defined to be the work priority of institutions and organizations responsible in the area of agriculture and equity issuance in the country. In this study, the possibility of provision of the Cadastral mapping of agriculture by a integration of the data of the remote sensing and ...

متن کامل

Integration of Remote Sensing and the GIS-based Methods for Provision of Cadastral Mapping of Agricultural Areas of Ardakan City

In the fifth development plan establishment, establishment of the Cadastre System of agriculture nationwide has been defined to be the work priority of institutions and organizations responsible in the area of agriculture and equity issuance in the country. In this study, the possibility of provision of the Cadastral mapping of agriculture by a integration of the data of the remote sensing and ...

متن کامل

Mapping cardiac fiber orientations from high-resolution DTI to high-frequency 3D ultrasound

The orientation of cardiac fibers affects the anatomical, mechanical, and electrophysiological properties of the heart. Although echocardiography is the most common imaging modality in clinical cardiac examination, it can only provide the cardiac geometry or motion information without cardiac fiber orientations. If the patient's cardiac fiber orientations can be mapped to his/her echocardiograp...

متن کامل

Remote sensing technology for mapping and monitoring vegetation cover (Case study: Semirom-Isfahan, Iran)

To determine the suitable indices for vegetation cover and production assessment based on the remote sensing data, simultaneous digital data with field data belonging to the spring rangeland of the Semirom-Isfahan province were analyzed. During two years of monitoring the annual, grass, forb, and shrub vegetation cover and the total production data from 86 were collected. The Global Positioning...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 1 2  شماره 

صفحات  -

تاریخ انتشار 2008