Quantitative evaluation of computed high B value diffusion-weighted magnetic resonance imaging of the prostate.
نویسندگان
چکیده
OBJECTIVES Computed diffusion-weighted magnetic resonance imaging (cDWI) refers to the synthesizing of arbitrary b value diffusion-weighted images (DWI) from a set of measured b value images by voxelwise fitting. The objectives of this study were to quantitatively analyze the noise and the contrast-to-noise ratio (CNR) in cDWI as a function of b value by numerical simulations and by measurements in patients with prostate cancer and to compare cDWI to directly measured DWI at a b value of 1400 s/mm2. MATERIALS AND METHODS Numerical simulations were performed to assess image noise and CNR in both cDWI and regular DWI. Forty-two patients with prostate cancer (age, 51-73 years; prostate specific antigen level, 0.5-30 ng/mL; and biopsy Gleason score, 6-9) received 2 DWI examinations at 3.0 T (one with b values of 100, 500, and 1400 s/mm2 and another with b values of 0, 100, 400, and 800 s/mm2) to create cDWI images at arbitrary b values, both with and without incorporating a b value of 0 s/mm2 in their calculation. Regions of interest were drawn to compare the scan time adjusted CNR (CNR eff) between cDWI and directly measured DWI at b = 1400 s/mm2 on tumor-suspicious lesions and normal-appearing regions. RESULTS In the numerical simulations, noise depended strongly on the b value, the diffusion coefficient, and the signal intensity at a b value of 0 s/mm2 in cDWI but not in regular DWI. The CNR between simulated tumor and normal regions showed a continuous increase with increasing b value. Both these findings were also observed in tumor-suspicious and normal-appearing regions in in vivo data. In vivo prostate DWI at a b value of 1400 s/mm2 showed a similar CNR eff between the tumor-suspicious regions and the normal-appearing tissue in cDWI as in the directly measured DWI (P = 0.395). CONCLUSIONS The CNR eff between tumor-suspicious and normal-appearing prostate tissue in DWI images at a b value of 1400 s/mm2 is comparable in cDWI and directly measured DWI. Computed DWI at even higher b values, calculated from measured images with b values between 0 and 800 s/mm2, yields higher CNR eff than measured DWI, which may be of clinical aid in the management of prostate cancer.
منابع مشابه
Signal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer
Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characterization. Objective: To assess based on histopathological findings of transrectal ultrasound (TRUS)-guided prostate biopsy as a reference, an...
متن کاملبررسی ارزش Diffusion Weighted Imaging در تصاویر MRI برای تشخیص سرطان پروستات
Background: Prostate cancer is the third leading cause of death and is the most common cause of cancer in elderly men. Regarding to the low accuracy of screening methods such as prostate-specific antigen (PSA), Digital Rectal Examination (DRE) and trans rectal ultrasound (TRUS) in detection and localization of tumor, Magnetic Resonance Imaging (MRI) and Diffusion Weighted Imaging (DWI) attracte...
متن کاملThe Utility of Diffusion Weighted Magnetic Resonance Imaging in Detection of the Origin of the Brain Solid Metastatic Tumors
Background: Early diagnosis of brain tumors has significant effect on the treatment process. Brain metastatic tumors are usually diagnosed following the neurological symptoms in patients or incidentally after Computerized Tomography (CT) scan and Magnetic Resonance Imaging (MRI) requests of the brain. Objectives: Implementation of a new method for being informed about the origin of brain tumors...
متن کاملDetecting prostate cancer and prostatic calcifications using advanced magnetic resonance imaging
Prostate cancer and prostatic calcifications have a high incidence in elderly men. We aimed to investigate the diagnostic capabilities of susceptibility-weighted imaging in detecting prostate cancer and prostatic calcifications. A total number of 156 men, including 34 with prostate cancer and 122 with benign prostate were enrolled in this study. Computed tomography, conventional magnetic resona...
متن کاملEvaluation of Diffusion Anisotropy and Diffusion Shape in Grading of Glial Tumors
Background: The most common primary tumors of brain are gliomas. Grading of tumor is vital for designing proper treatment plans. The gold standard choice to determine the grade of glial tumor is biopsy which is an invasive method.Objective: In this study, we try to investigate the role of fractional anisotropy (diffusion anisotropy) and linear anisotropy ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative radiology
دوره 48 11 شماره
صفحات -
تاریخ انتشار 2013