Titration with automatic continuous positive airway pressure in obstructive sleep apnea.
نویسندگان
چکیده
BACKGROUND AND OBJECTIVE Autotitrating positive airway pressure (APAP) is an accepted titration method to determine the optimal positive airway pressure (PAP), for the treatment of obstructive sleep apnea (OSA). The required duration of APAP monitoring to determine a fixed continuous positive airway pressure level still remains to be established. We aimed to evaluate the variation in PAP level, delivered by APAP devices, at different periods of treatment, to determine the APAP treatment duration required to reach an effective and stable PAP level. METHODS A cross-sectional study of 62 patients newly diagnosed with OSA were evaluated after 3 months of APAP therapy. APAP data corresponding to the first day (D1), first week (W1), seventh week (W7) and twelfth week (W12) under APAP therapy was collected. For the analysis of the pressure behaviour, the difference of P95th pressure level between W12 and W7 (P W12-W7), W12 and W1 (P W12-W1) and W12 and D1 (P W12-D1) was calculated. RESULTS There was a high correlation in P95th pressure level between D1 and W12 (r=0.771; p>0.0001), W1 and W12 (r=0.817; p>0.0001), and W7 and W12 (r=0.926; p>0.0001). This correlation progressively increased with APAP use. A significance difference was found in concordance between P W12-W7 and P W12-D1 (p=0.046) within the pressure range ±2cmH2O. However there was no significant difference in concordance between P W12-W7 and P W12-W1. CONCLUSIONS One week of APAP therapy seems sufficient to determine an effective and stable PAP level, within the pressure range ±2cmH2O.
منابع مشابه
Factors Affecting Patients’ Adherence to Continuous Positive Airway Pressure Therapy for Obstructive Sleep Apnea Disorder: A Multi-Method Approach
Background: Continuous positive airway pressure (CPAP) is the gold standard therapy for treating obstructive sleep apnea (OSA) disorder. However, patients’ adherence to its regular use is poor. The present study aimed to determine the adherence rate to CPAP therapy by identifying factors affecting its regular use and its associated problems and discomforts among a sample population in Mashhad (...
متن کاملObstructive Sleep Apnea in Ischemic Stroke patients
OBJECTIVE To investigate the prevalence of obstructive sleep apnea in patients with ischemic stroke and to evaluate the effectiveness of nasal continuous positive airway pressure treatment. METHODS Overnight polysomnography was performed by a computerized system in 19 subjects with ischemic stroke. Patients with an apnea-hypopnea index > or = 5 were considered to have obstructive sleep apnea....
متن کاملRelative occurrence of flow limitation and snoring during continuous positive airway pressure titration.
OBJECTIVES To examine the relative temporal appearance of flow limitation and snoring during continuous positive airway pressure (CPAP) titration, compare their sensitivity as indicators of airway obstruction, and assess their relative utility as feedback variables for automatic titration of CPAP. DESIGN Retrospective review of data. SETTING University teaching hospital. PATIENTS Fifty-th...
متن کاملAmbulatory titration of continuous positive airway pressure was as effective as polysomnography for obstructive sleep apnea.
متن کامل
A system to generate simultaneous forced oscillation and continuous positive airway pressure.
Assessment of airway obstruction in patients with obstructive sleep apnoea (OSA) subjected to continuous positive airway pressure (CPAP) may be carried out using the forced oscillation technique (FOT). To facilitate routine application of forced oscillation (FO) in sleep studies, our aim was to design a system capable of generating CPAP and applying FOT simultaneously. We constructed a prototyp...
متن کاملAutomatic CPAP titration with different self-setting devices in patients with obstructive sleep apnoea.
Autotitrating continuous positive airway pressure (CPAP) devices automatically adjust the pressure according to upper airway obstructions. The aim of this study was to compare the treatment effects of different automatic CPAP devices (AutoSet, Horizon and Virtuoso) with conventional CPAP in patients with obstructive sleep apnoea independently of financial manufacturer support. Twelve male patie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista portuguesa de pneumologia
دوره 23 4 شماره
صفحات -
تاریخ انتشار 2017