Fast method for inverse determination of optical parameters from two measured signals.

نویسندگان

  • Xun Chen
  • Yuanming Feng
  • Jun Q Lu
  • Xiaohui Liang
  • Jue Ding
  • Yong Du
  • Xin-Hua Hu
چکیده

Solving inverse problems requires multiple forward calculations of measured signals. We present a fast method combining graphic processing unit-accelerated Monte Carlo simulations of individual photons and a new perturbation scheme for a 300-fold speedup in comparison to conventional CPU-based approaches. The method allows rapid calculations of the diffuse reflectance and transmittance signals from a turbid sample of absorption coefficient μ(a), scattering coefficient μ(s), and anisotropy factor g based on the principle of correlated sampling. To demonstrate its strong utility, we have applied the method for determining the optical parameters of diluted intralipid samples with satisfactory results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A primary method for determination of optical parameters of turbid samples and application to intralipid between 550 and 1630 nm.

The lack of a primary method for determination of optical parameters remains a significant barrier in optical study of turbid media. We present a complete system of experimental setups and Monte Carlo modeling tools for fast and accurate solution of the inverse problem from the measured signals of homogeneous turbid samples. The calibration of the instrument and validation of the Monte Carlo mo...

متن کامل

Designing and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals

Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...

متن کامل

INVERSE FREQUENCY RESPONSE ANALYSIS FOR PIPELINES LEAK DETECTION USING THE PARTICLE SWARM OPTIMIZATION

Inverse Transient Analysis (ITA) is a powerful approach for leak detection of pipelines. When the pipe transient flow is analyzed in frequency domain the ITA is called Inverse Frequency Response Analysis (IFRA). To implement an IFRA for leak detection, a transient state is initiated in the pipe by fast closure of the downstream end valve. Then, the pressure time history at the valve location is...

متن کامل

Protection Scheme of Power Transformer Based on Time–Frequency Analysis and KSIR-SSVM

The aim of this paper is to extend a hybrid protection plan for Power Transformer (PT) based on MRA-KSIR-SSVM. This paper offers a new scheme for protection of power transformers to distinguish internal faults from inrush currents. Some significant characteristics of differential currents in the real PT operating circumstances are extracted. In this paper, Multi Resolution Analysis (MRA) is use...

متن کامل

Determination of Optical Properties in Germanium Carbon Coatings Deposited by Plasma Enhanced Chemical Vapor Deposition

In this research, Germanium-carbon coatings were deposited on ZnS substrates by plasma enhanced chemical vapor deposition (PECVD) using GeH4 and CH4 precursors. Optical parameters of the Ge1-xCx coating such as refractive index, Absorption coefficient, extinction coefficient and band gap were measured by the Swanepoel method based on the transmittance spectrum. The results showed that the refra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics letters

دوره 38 12  شماره 

صفحات  -

تاریخ انتشار 2013