Ray-driven analytical fan-beam SPECT reconstruction with nonuniform attenuation
نویسندگان
چکیده
Single-photon emission computed tomography (SPECT) is based on the measurement of radiation emitted by a radiotracer injected into the patient. Because of photoelectric absorption and Compton scatter, the γ photons are attenuated inside the body before arriving at the detector. A quantitative reconstruction must consider the attenuation, which is usually non-uniform. Novikov and Natterer had derived an explicit formula for nonuniformly attenuated SPECT reconstruction of parallel-hole collimators. In this paper, we extend their researches to fan-beam collimators. Because any ray in fan-beam geometry can be treated as a ray in parallel-beam geometry, we derived a ray-driven analytical fan-beam reconstruction formula with non-uniform attenuation. Its accuracy is demonstrated computer simulation experiments.
منابع مشابه
An Analytical Inversion of the Nonuniformly Attenuated Radon Transform With Variable Focal-Length Fan-Beam Collimators
Single photon emission computed tomography (SPECT) is based on the measurement of radiation emitted by a radiotracer injected into the patient. Because of photoelectric absorption and Compton scatter, the gamma photons are attenuated inside the body before arriving at the detector. A quantitative reconstruction must consider the attenuation, which is usually nonuniform. Novikov has derived an e...
متن کاملEvaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT Images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators
Objective(s): The purpose of this study was to examine the optimal reconstruction parameters for brain dopamine transporter SPECT images obtained with a fan beam collimator and compare the results with those obtained by using parallel-hole collimators.Methods: Data acquisition was performed using two SPECT/CT devices, namely a Symbia T6 and an Infinia Hawkeye 4 (device A and B) equipped with fa...
متن کاملAnalytical Solution to 3D SPECT Reconstruction with Non-uniform Attenuation, Scatter, and Spatially-variant Resolution Variation for Variable Focal-length Fan-beam Collimators
In the past decades, analytical (non-iterative) methods have been extensively investigated and developed for the reconstruction of three-dimensional (3D) single-photon emission computed tomography (SPECT). However, it becomes possible only recently when the exact analytic non-uniform attenuation reconstruction algorithm was derived. Based on the explicit inversion formula for the attenuated Rad...
متن کاملExact fan-beam and 4pi-acquisition cone-beam SPECT algorithms with uniform attenuation correction.
This paper presents analytical fan-beam and cone-beam reconstruction algorithms that compensate for uniform attenuation in single photon emission computed tomography. First, a fan-beam algorithm is developed by obtaining a relationship between the two-dimensional (2D) Fourier transform of parallel-beam projections and fan-beam projections. Using this relationship, 2D Fourier transforms of equiv...
متن کاملAn analytical algorithm for skew-slit imaging geometry with nonuniform attenuation correction.
The pinhole collimator is currently the collimator of choice in small animal single photon emission computed tomography (SPECT) imaging because it can provide high spatial resolution and reasonable sensitivity when the animal is placed very close to the pinhole. It is well known that if the collimator rotates around the object (e.g., a small animal) in a circular orbit to form a cone-beam imagi...
متن کامل