A new insole measurement system to detect bending and torsional moments at the human foot during footwear condition: a technical report

نویسندگان

  • Thomas Stief
  • Klaus Peikenkamp
چکیده

BACKGROUND Stress occurring at the feet while wearing footwear is often determined using pressure measurement systems. However, other forms of stress, such as bending, torsional and shear loadings, cannot be detected in shoes during day-to-day activities. Nevertheless, the detection of these types of stresses would be helpful for understanding the mechanical aspects of various kinds of hard and soft tissue injuries. Therefore, we describe the development of a new measuring device that allows the reliable determination of bending and torsional load at the foot in shoes. METHODS The system consists of a measuring insole and an analogue device with Bluetooth interface. The specific shape of the insole base layer, the positions of the strain gauges, and the interconnections between them have all been selected in such a way so as to isolate bending and torsional moment detections in the medial and lateral metatarsal region. The system was calibrated using a classical two-point test procedure. A single case study was executed to evaluate the new device for practical use. This application consisted of one subject wearing neutral shoes walking on a treadmill. RESULTS The calibration results (coefficients of determination R(2) > 0.999) show that bending and torsional load can be reliably detected using the measurement system presented. In the single case study, alternating bending and torsional load can be detected during walking, and the shape of the detected bending moments can be confirmed by the measurements of Arndt et al. (J Biomech 35:621-8, 2002). CONCLUSIONS Despite some limitations, the presented device allows for the reliable determination of bending and torsional stresses at the foot in shoes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Altering footwear type influences gait during level walking and downhill transitions.

The purpose of our study was to determine if altering the insoles within footwear or walking barefoot, as an attempt to increase or decrease cutaneous stimuli, would improve dynamic balance during a hill-walking task. We hypothesize that compared with foam insoles or iced bare feet, textured insoles or bare feet will result in greater speeds, longer step lengths, narrower step width, shorter st...

متن کامل

An analysis of functional insole on foot pressure distribution of shape memory material combinations

The purpose of this study was to analyze foot pressure distribution of shape memory materials functional insole. Comfort is an important aspect for footwear and insole. Footwear and insole comfort has an influence on injury [1,2]. The development of new materials is considered as the important point for manufacturing functional insole [3,4]. Ten healthy male (mean height: 174.7±4.0 cm, mean bod...

متن کامل

اثر آنی کفی طبی بر نرخ بارگذاری، ایمپالس و گشتاور آزاد در کودکان پسر دارای کف پای صاف: یک مطالعه کار آزمایی بالینی

Background and Objectives: The prevalence of flexible flat foot in children was reported between 20 -78% in previous studies. Flat foot can result into mechanical deviations in lower limb alignment during walking. The purpose of this study was to evaluate the immediate effects of medical insole on loading rate, impulse, and free moment in children with flat foot during walking. Material and M...

متن کامل

Design and pilot testing of the DVAISeattle Footwear System for diabetic patients with foot insensitivity

Clinical epidemiology studies suggest the majority of lower limb amputations were preceded by a minor traumatic event, often footwear-related, and lower limb ulcers . To reduce foot trauma and ulcers, the diabetic patient with foot insensitivity has unique footwear needs . To address these needs for patients not requiring custom shoes, the DVAISeattle Footwear System was developed. The six comp...

متن کامل

Design and pilot testing of the DVA/Seattle Footwear System for diabetic patients with foot insensitivity.

Clinical epidemiology studies suggest the majority of lower limb amputations were preceded by a minor traumatic event, often footwear-related, and lower limb ulcers. To reduce foot trauma and ulcers, the diabetic patient with foot insensitivity has unique footwear needs. To address these needs for patients not requiring custom shoes, the DVA/Seattle Footwear System was developed. The six compon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2015