Effect of red blood cell rigidity on tumor blood flow: increase in viscous resistance during hyperglycemia.

نویسندگان

  • E M Sevick
  • R K Jain
چکیده

Elevated glucose level and low pH have been shown to increase red blood cell (RBC) rigidity. This increased rigidity has been proposed as one factor which mediates the tumor blood flow (TBF) reduction during hyperglycemia by (a) causing RBC entrapment and hence increasing geometric resistance and (b) increasing viscous resistance to blood flow. However, due to the inability to measure these resistances in vivo in tumors directly, the relative contribution of RBC rigidity in TBF reduction has not been quantified. In the present study, blood flow resistance was measured in "tissue-isolated" mammary adenocarcinoma R3230AC perfused ex vivo with (a) normally deformable, (b) glutaraldehyde-hardened, and (c) glucose-incubated RBC suspensions. Flow resistance measured during tumor perfusion with Krebs-Henseleit buffer prior to and following perfusion with the glutaraldehyde-hardened RBC suspensions showed no significant change, suggesting constant geometric resistance and lack of RBC entrapment. Instead, our measurements indicated increased viscous resistance with loss of deformability due to glutaraldehyde and glucose incubation even though glucose incubation did not significantly alter the apparent blood viscosity measured in vitro. Thus, the TBF reduction during hyperglycemia may be due to subtle changes in RBC deformability. These results suggest the development of strategies to increase the delivery of drugs or oxygen must take into account any changes in intratumor viscous resistance. For example, the increase in the oxygen-carrying capacity of blood using RBC transfusion or fluorocarbon emulsions may be offset by the increase in viscous resistance and the corresponding reduction in TBF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blood flow and venous pH of tissue-isolated Walker 256 carcinoma during hyperglycemia.

Hemodynamic (blood flow rate, hematocrit, hemoglobin concentration, and blood viscosity) and pH responses to glucose (6 g/kg, i.p.) injections were studied in ten Walker 256 carcinoma tumors (0.5-1.8 g) grown in the "tissue-isolated" tumor preparation. A maximum blood flow reduction of 57 +/- 19% (SD) occurred concurrently with an increase in tumor arterial-venous blood pH difference 20-30 min ...

متن کامل

Mathematical Analysis of MHD Flow of Blood in Very Narrow Capillaries (RESEARCH NOTE)

A mathematical model for blood flow in narrow capillaries under the effect of transverse magnetic field has been investigated. It is assumed that there is a lubricating layer between red blood cells and tube wall. The transient flow of the fit red blood cell surrounded by plasma annulus in the narrow capillary is considered. The analysis of fluid flow between red cell and tube wall, when the ce...

متن کامل

Viscous Resistance to Blood Flow in Solid Tumors: Effect of Hematocrit on Intratumor Blood Viscosity1

Blood flow rate in a vascular network is proportional to the arteriovenous pressure difference and inversely proportional to the geometric and viscous resistances. We have recently shown that the geometric resistance to blood flow increases with increasing tumor size and/or decreasing arterial pressure. In this study, the viscous resistance to blood flow within tumor microvasculature was determ...

متن کامل

Viscous resistance to blood flow in solid tumors: effect of hematocrit on intratumor blood viscosity.

Blood flow rate in a vascular network is proportional to the arteriovenous pressure difference and inversely proportional to the geometric and viscous resistances. We have recently shown that the geometric resistance to blood flow increases with increasing tumor size and/or decreasing arterial pressure. In this study, the viscous resistance to blood flow within tumor microvasculature was determ...

متن کامل

A Biomechanical Approach for the Study of Deformation of Red Cells in Narrow Capillaries

This model focuses on the behavior of capillary-tissue fluid exchange system when the diameter of the capillary is less than that of red cell. In vivo and in vitro observations indicate that the width of the gap between the red cell and the vessel wall is generally small compared to the radius of the capillary for a single file flow of red cell in narrow vessel, particularly if the vessel diame...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cancer research

دوره 51 10  شماره 

صفحات  -

تاریخ انتشار 1991