Superior liver sparing by combined coplanar/noncoplanar volumetric-modulated arc therapy for hepatocellular carcinoma: a planning and feasibility study.

نویسندگان

  • Yi-Chun Tsai
  • Chiao-Ling Tsai
  • Feng-Ming Hsu
  • Wu Jian-Kuen
  • Wu Chien-Jang
  • Jason Chia-Hsien Cheng
چکیده

Compared with step-and-shoot intensity-modulated radiotherapy (sIMRT) and tomotherapy, volumetric-modulated arc therapy (VMAT) allows additional arc configurations in treatment planning and noncoplanar (NC) delivery. This study was first to compare VMAT planning with sIMRT planning, and the second to evaluate the toxicity of coplanar (C)/NC-VMAT treatment in patients with hepatocellular carcinoma (HCC). Fifteen patients with HCC (7 with left-lobe and 8 with right-lobe tumors) were planned with C-VMAT, C/NC-VMAT, and sIMRT. The median total dose was 49Gy (range: 40 to 56Gy), whereas the median fractional dose was 3.5Gy (range: 3 to 8Gy). Different doses/fractionations were converted to normalized doses of 2Gy per fraction using an α/β ratio of 2.5. The mean liver dose, volume fraction receiving more than 10Gy (V10), 20Gy (V20), 30Gy (V30), effective volume (Veff), and equivalent uniform dose (EUD) were compared. C/NC-VMAT in 6 patients was evaluated for delivery accuracy and treatment-related toxicity. Compared with sIMRT, both C-VMAT (p = 0.001) and C/NC-VMAT (p = 0.03) had significantly improved target conformity index. Compared with C-VMAT and sIMRT, C/NC-VMAT for treating left-lobe tumors provided significantly better liver sparing as evidenced by differences in mean liver dose (p = 0.03 and p = 0.007), V10 (p = 0.003 and p = 0.009), V20 (p = 0.006 and p = 0.01), V30 (p = 0.02 and p = 0.002), Veff (p = 0.006 and p = 0.001), and EUD (p = 0.04 and p = 0.003), respectively. For right-lobe tumors, there was no difference in liver sparing between C/NC-VMAT, C-VMAT, and sIMRT. In all patients, dose to more than 95% of target points met the 3%/3mm criteria. All 6 patients tolerated C/NC-VMAT and none of them had treatment-related ≥ grade 2 toxicity. The C/NC-VMAT can be used clinically for HCC and provides significantly better liver sparing in patients with left-lobe tumors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coplanar versus noncoplanar intensity‐modulated radiation therapy (IMRT) and volumetric‐modulated arc therapy (VMAT) treatment planning for fronto‐temporal high‐grade glioma†

The purpose of this study was to compare dosimetric and radiobiological parameters of treatment plans using coplanar and noncoplanar beam arrangements in patients with fronto-temporal high-grade glioma (HGG) generated for intensity-modulated radiotherapy (IMRT) or volumetric-modulated arc therapy (VMAT). Ten cases of HGG overlapping the optic apparatus were selected. Four separate plans were cr...

متن کامل

Assessing the role of volumetric‐modulated arc therapy in hepatocellular carcinoma

The role of volumetric-modulated arc therapy (VMAT) in hepatocellular carcinoma (HCC) remains controversial. The purpose of this study was to determine the potential clinical role of VMAT compared with three-dimensional conformal radiotherapy (3D CRT) for liver irradiation. Four-dimensional CT scans of 24patients with unresectable HCC were included and divided into two groups: (1) adjacent grou...

متن کامل

Viability of Noncoplanar VMAT for liver SBRT compared with coplanar VMAT and beam orientation optimized 4π IMRT

PURPOSE The 4π static non-coplanar radiotherapy delivery technique has demonstrated better normal tissue sparing and dose conformity than the clinically used volumetric modulated arc therapy (VMAT). It is unclear whether this is a fundamental limitation of VMAT delivery or the coplanar nature of its typical clinical plans. The dosimetry and the limits of normal tissue toxicity constrained dose ...

متن کامل

A dosimetric comparison of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer

BACKGROUND To compare dosimetric parameters of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer with regard to the coverage of planning target volume (PTV) and the sparing of organs at risk (OAR). METHODS Ten patients with nasal cavity or paranasal sinus cancer were re-planned by VMAT (two-arc) plan an...

متن کامل

Four-dimensional CT-based evaluation of volumetric modulated arc therapy for abdominal lymph node metastasis from hepatocellular carcinoma

This study aimed to identify the potential benefits and limitations of a new volumetric modulated arc therapy (VMAT) planning system in Monaco, compared with conventional intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3DCRT). Four-dimensional CT scans of 13 patients with abdominal lymph node metastasis from hepatocellular carcinoma were selected. Internal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical dosimetry : official journal of the American Association of Medical Dosimetrists

دوره 38 4  شماره 

صفحات  -

تاریخ انتشار 2013