ProDisc artificial total lumbar disc replacement: introduction and early results from the United States clinical trial.

نویسندگان

  • Rick B Delamarter
  • David M Fribourg
  • Linda E A Kanim
  • Hyun Bae
چکیده

STUDY DESIGN Multicenter prospective randomized study of artificial disc replacement (ProDisc) versus circumferential fusion (standard of care) for one- and two-level degenerative disc disease. This is an interim analysis on patients seen at the Spine Institute Saint John's Health Center, Santa Monica, California. OBJECTIVES To evaluate early pain and functional outcomes of patients treated with disc replacement or fusion and to assess the capacity of this intervertebral disc replacement for preserving motion in the lumbar spine. SUMMARY OF BACKGROUND DATA Disc replacement is intended to reduce pain via removal of the diseased disc while restoring physiologic motion and height at the affected level. The long-term physiologic advantage of disc replacement to fusion is that preservation of motion may prevent additional degeneration at adjacent levels. METHODS Patients meeting inclusion criteria were consented for study. Randomization was performed using a 2 to 1 ratio of disc replacement procedure to a fusion procedure. Patients rated their pain on the Visual Analogue Scale and completed the Oswestry Disability Index questionnaire. Radiographs were taken. Assessments were made before surgery and after surgery at 6 weeks, 3 months, 6 months, and 1 year (ongoing). Changes from preoperative pain, disability, or motion were separately evaluated as a function of treatment using repeated measures mixed design analysis of variance. RESULTS This analysis includes data up to 6 months from the first 53 randomized patients. There were 35 patients who underwent disc replacements, and 18 patients had fusion procedures. Disc replacement patients had a significant reduction in pain and disability at earlier evaluations. By 6 months, the relative improvement on both the Visual Analogue Scale and Oswestry (both, P < 0.05) were similar for disc replacement and fusion patients. Greater motion was found at L4-L5 for disc replacement patients (P < 0.05) than fusion patients. A similar trend was noted at L5-S1 (P was not significant). CONCLUSIONS Disc replacement patients reported significantly less pain (Visual Analogue Scale) and disability (Oswestry) in the early period following surgery compared to fusion patients. This difference disappeared by 6 months. When compared to fusion, the disc replacement allowed preservation of motion at L4-L5 with a similar trend at L5-S1.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two- to 3-Year Follow-Up of ProDisc-L: Results From a Prospective Randomized Trial of Arthroplasty Versus Fusion

BACKGROUND Although total disc replacement has been performed for years outside the United States, relatively little available data address clinical outcomes, particularly data from prospective studies. We report the 24- to 36-month follow-up of one center's experience with the ProDisc-L artificial disc as part of a prospective, randomized trial comparing total disc arthroplasty to combined ant...

متن کامل

Clinical study to evaluate the safety and effectiveness of the Aesculap Activ-L™ artificial disc in the treatment of degenerative disc disease

BACKGROUND The objective of this clinical study is to evaluate the safety and effectiveness of the Activ-L Artificial Disc for treatment of single-level degenerative disc disease of the lumbar spine in patients who have been unresponsive to at least six months of prior conservative care. The hypothesis of the study is that the Activ-L Disc is non-inferior to the control (the Charité Artificial ...

متن کامل

The activL® Artificial Disc: a next-generation motion-preserving implant for chronic lumbar discogenic pain

Degeneration of the lumbar intervertebral discs is a leading cause of chronic low back pain in adults. Treatment options for patients with chronic lumbar discogenic pain unresponsive to conservative management include total disc replacement (TDR) or lumbar fusion. Until recently, only two lumbar TDRs had been approved by the US Food and Drug Administration - the Charité Artificial Disc in 2004 ...

متن کامل

Artificial Spinal Discs for Single-Level Lumbar or Cervical Disc Disease

© 2005 Kaiser Foundation Health Plan of Washington. All Rights Reserved. Back to Top Kaiser Foundation Health Plan of Washington Clinical Review Criteria Artificial Spinal Discs for Single-Level Lumbar or Cervical Disc Disease • BryanTM • CharitéTM • PrestigeTM Artificial Discs • ProDisc-CTM • ProDisc-LTM • Two-level cervical artificial disc replacement for the treatment of cervical degenerativ...

متن کامل

The Correlation between Insertion Depth of Prodisc-C Artificial Disc and Postoperative Kyphotic Deformity: Clinical Importance of Insertion Depth of Artificial Disc

OBJECTIVE This study was designed to investigate the correlation between insertion depth of artificial disc and postoperative kyphotic deformity after Prodisc-C total disc replacement surgery, and the range of artificial disc insertion depth which is effective in preventing postoperative whole cervical or segmental kyphotic deformity. METHODS A retrospective radiological analysis was performe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 28 20  شماره 

صفحات  -

تاریخ انتشار 2003