A ug 2 00 7 Air fluorescence measurements in the spectral range 300 - 420 nm using a 28 . 5 GeV electron beam

نویسنده

  • A. Zech
چکیده

Measurements are reported of the yield and spectrum of fluorescence, excited by a 28.5 GeV electron beam, in air at a range of pressures of interest to ultra-high energy cosmic ray detectors. The wavelength range was 300 420 nm. System calibration has been performed using Rayleigh scattering of a nitrogen laser beam. In atmospheric pressure dry air at 304 K the yield is 20.8 ± 1.6 photons per MeV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Air fluorescence measurements in the spectral range 300–420 nm using a 28.5 GeV electron beam

Measurements are reported of the yield and spectrum of fluorescence, excited by a 28.5 GeV electron beam, in air at a range of pressures of interest to ultrahigh energy cosmic ray detectors. The wavelength range was 300 420 nm. System calibration has been performed using Rayleigh scattering of a nitrogen laser beam. In atmospheric pressure dry air at 304 K the yield is 20.8 ± 1.6 photons per MeV.

متن کامل

Measurement of air and nitrogen fluorescence light yields induced by electron beam for UHECR experiments

Most of the Ultra High Energy Cosmic Ray (UHECR) experiments and projects (HiRes, AUGER, TA, EUSO, TUS,...) use air fluorescence to detect and measure extensive air showers (EAS). The precise knowledge of the Fluorescence Light Yield (FLY) is of paramount importance for the reconstruction of UHECR. The MACFLY Measurement of Air Cherenkov and Fluorescence Light Yield experiment has been designed...

متن کامل

x / 02 08 01 2 v 1 9 A ug 2 00 2 Development of a Momentum Determined Electron Beam in the 1 - 45 GeV Range

A beam line for electrons with energies in the range of 1 to 45 GeV, low contamination of hadrons and muons and high intensity up to 10 per accelerator spill at 27 GeV was setup at U70 accelerator in Protvino, Russia. A beam tagging system based on drift chambers with 160 μm resolution was able to measure relative electron beam momentum precisely. The resolution σp/p was 0.13% at 45 GeV where m...

متن کامل

Measurement of Pressure Dependent Fluorescence Yield of Air: Calibration Factor for UHECR Detectors

In a test experiment at the Final Focus Test Beam of the Stanford Linear Accelerator Center, the fluorescence yield of 28.5 GeV electrons in air and nitrogen was measured. The measured photon yields between 300 and 400 nm at 1 atm and 29C are Y (760 Torr) = 4.42 ± 0.73 and Y (760 Torr)2 = 29.2± 4.8 photons per electron per meter. Assuming that the fluorescence yield is proportional to the energ...

متن کامل

ar X iv : h ep - p h / 02 09 00 7 v 1 3 1 A ug 2 00 2 Measuring the initial electron beam polarization

The investigation of e γ → ν W process is crucial for a possible high energy eγ or γγ collider since it offers the possibility for both new physics discovery and precision measurements. The polarization of the initial beam is a limiting factor for the systematic errors in both cases. This note addresses the feasibility of making a measurement of the initial electron beam polarization with relat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008