Efficiency of hydrogen peroxide in improving disinfection of ICU rooms

نویسندگان

  • Caroline Blazejewski
  • Frédéric Wallet
  • Anahita Rouzé
  • Rémi Le Guern
  • Sylvie Ponthieux
  • Julia Salleron
  • Saad Nseir
چکیده

INTRODUCTION The primary objective of this study was to determine the efficiency of hydrogen peroxide (H₂O₂) techniques in disinfection of ICU rooms contaminated with multidrug-resistant organisms (MDRO) after patient discharge. Secondary objectives included comparison of the efficiency of a vaporizator (HPV, Bioquell) and an aerosolizer using H₂O₂, and peracetic acid (aHPP, Anios) in MDRO environmental disinfection, and assessment of toxicity of these techniques. METHODS This prospective cross-over study was conducted in five medical and surgical ICUs located in one University hospital, during a 12-week period. Routine terminal cleaning was followed by H₂O₂ disinfection. A total of 24 environmental bacteriological samplings were collected per room, from eight frequently touched surfaces, at three time-points: after patient discharge (T0), after terminal cleaning (T1) and after H₂O₂ disinfection (T2). RESULTS In total 182 rooms were studied, including 89 (49%) disinfected with aHPP and 93 (51%) with HPV. At T0, 15/182 (8%) rooms were contaminated with at least 1 MDRO (extended spectrum β-lactamase-producing Gram-negative bacilli 50%, imipenem resistant Acinetobacter baumannii 29%, methicillin-resistant Staphylococcus aureus 17%, and Pseudomonas aeruginosa resistant to ceftazidime or imipenem 4%). Routine terminal cleaning reduced environmental bacterial load (P <0.001) without efficiency on MDRO (15/182 (8%) rooms at T0 versus 11/182 (6%) at T1; P = 0.371). H₂O₂ technologies were efficient for environmental MDRO decontamination (6% of rooms contaminated with MDRO at T1 versus 0.5% at T2, P = 0.004). Patient characteristics were similar in aHPP and HPV groups. No significant difference was found between aHPP and HPV regarding the rate of rooms contaminated with MDRO at T2 (P = 0.313). 42% of room occupants were MDRO carriers. The highest rate of rooms contaminated with MDRO was found in rooms where patients stayed for a longer period of time, and where a patient with MDRO was hospitalized. The residual concentration of H₂O₂ appears to be higher using aHPP, compared with HPV. CONCLUSIONS H₂O₂ treatment is efficient in reducing MDRO contaminated rooms in the ICU. No significant difference was found between aHPP and HPV regarding their disinfection efficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the efficacy of a hydrogen peroxide dry-mist disinfection system and sodium hypochlorite solution for eradication of Clostridium difficile spores.

OBJECTIVE To compare a hydrogen peroxide dry-mist system and a 0.5% hypochlorite solution with respect to their ability to disinfect Clostridium difficile-contaminated surfaces in vitro and in situ. DESIGN Prospective, randomized, before-after trial. SETTING Two French hospitals affected by C. difficile. INTERVENTION In situ efficacy of disinfectants was assessed in rooms that had housed ...

متن کامل

Effectiveness of a novel ozone-based system for the rapid high-level disinfection of health care spaces and surfaces.

BACKGROUND Vapor-based fumigant systems for disinfection of health care surfaces and spaces is an evolving technology. A new system (AsepticSure) uses an ozone-based process to create a highly reactive oxidative vapor with broad and high-level antimicrobial properties. METHODS Ozone gas at 50-500 ppm was combined with 3% hydrogen peroxide vapor in a test chamber and upscaled in rooms measurin...

متن کامل

Evaluating the Efficiency of the Fenton-Ultrasonic Process in Degradation of Trihalomethanes Precursors from Aqueous Environments Using Zero Iron by Response Surface Method

Background: The reaction of natural organic matters (NOMs) with chlorine in the conventional disinfection process results in disinfection by-products (DBP) such as trihalomethanes and haloacetic acids. Due to the potential health risks of trihalomethanes for public health, it has attracted a lot of attention. The purpose of this study is to investigate the performance of combined Fenton-ultraso...

متن کامل

مقایسه کارایی واکنش­‌گر فنتون و فنتون تغییر یافته با مس در گندزدایی  فاضلاب خام به منظور استفاده مجدد در کشاورزی

MicrosoftInternetExplorer4 Background and Objectives: Irrigation of agricultural crops using wastewater will increase, in some cases, their growth by 40 to 60 percent. However, this has a high risks for human health because of the presence of higher number of pathogenic organisms. The main purpose of this study was to investigate the feasibility use of Fenton and modified Fenton with coppe...

متن کامل

Hydrogen peroxide room disinfection – ready for prime time?

Non-manual techniques for terminal disinfection of hospital rooms have gained increasing interest in recent years as means to reduce transmission of multidrug-resistant organisms (MDROs). A prospective crossover study by Blazejewski and colleagues in five ICUs of a French academic hospital with a high prevalence of MDRO carriers showed that two different hydrogen peroxide (H2O2)-based non-touch...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2015