Analytical and Experimental Comparisons Between the Frequency-Modulated-Frequency-Shift Measurement and the Pulsed-Wave-Time-Shift Measurement Doppler Systems

نویسندگان

  • Jens E. Wilhjelm
  • Peder C. Pedersen
چکیده

In previous publications, a new echo-ranging Doppler system based on transmission of repetitive coherent frequency-modulated ͑FM͒ sinusoids in two different implementations was presented. One of these implementations, the frequency-modulated–frequency-shift measurement ͑FM–fsm͒ Doppler system is, in this paper, compared with its pulsed-wave counterpart, the pulsed-wave– time-shift measurement ͑PW–tsm͒ Doppler system. When using transmitted PW and FM signals with a Gaussian envelope, the parallelism between the two systems can be stated explicitly and comparison can be made between the main performance indices for the two Doppler systems. The performance of the FM and PW Doppler systems is evaluated by means of numerical simulation and measurements of actual flow profiles. The results indicate that the two Doppler systems have very similar levels of performance. LIST OF SYMBOLS B 0 ϭf 2 Ϫ f 1 , frequency excursion of transmitted signal B rms rms bandwidth of transmitted signal D nominal range ⌬D axial range cell distance defined by signal processing d (n) ϭd (0) ϩ␯nT r , range of scatterer at the onset of nth transmission f 0 center frequency of transmitted signal; for FM: f 0 ϭ(f 1 ϩ f 2)/2 f 1 ''start'' instantaneous frequency of transmitted sweep signal ͑@tϭ0͒ f 2 ''stop'' instantaneous frequency of transmitted sweep signal ͑@tϭt m ͒ ⌬ f a ϭ␶ 0 S 0 , change in position frequency between two consecutive fsm spectra f a (n) ϭ͑t (n) Ϫt s)S 0 , position ͑or center͒ frequency of the fsm spectrum f w ϭ(2⌬D/c)S 0 , width of spectral window in fsm signal processing S 0 ϭB 0 /t m , sweep rate of transmitted FM signal t (n) ϭ2d (n) /c, ultrasound round trip travel time for scat-terer at the onset of transmission number n t a (n) measure of rate of oscillations of the nth spectral cross-correlation function in the FM–fsm Doppler system t d (n) ϭt (n) Ϫt, difference between acoustic delay (t (n)) and system delay (t s) t m time duration of transmitted signal T r pulse or sweep repetition time t s ϭ2D/c, time delay corresponding to nominal range T w ϭ2⌬D/c, duration of time window in tsm signal processing ␯ velocity component of target ͑scatterer͒ along ultra-sound beam ␯ alias aliasing velocity in a psm Doppler system ␣ form factor for Gaussian envelope ␣ G ϭ2͑␣/t m ͒ 2 , combined form factor ␤ ϭ(cϪ␯)/(cϩ␯), Doppler compression factor ␥ frequency …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Altitude measurement using laser beam reflected from water surface

In this paper altitude measurement from water surface using laser beam is presented. Research data indicate that the reflection of infrared waves from water surface is about zero and it is less than 2% for visible radiations. Phase-shift and heterodyne technique was used for the measurement, and the laser beam ( mW p nm 10 , 700 = = l ) was modulated by a sine wave having a fixed frequency....

متن کامل

Echocardiographic Measurement of Systolic Time Intervals in Healthy Great Dane Dogs

Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Thirty healthy Great Dane dogs. Procedures- This study examined 30 clinically healthy Great Dane dogs by the twodimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. ...

متن کامل

Normal left ventricular systolic time intervals assessed by pulsed wave Doppler echocardiography in the Turkmen horse of Iran

The Turkmen horse is one of the oldest and purest breeds in the world. There is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. Pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. There were 26 stallions and 16 mares. The left ventricular isovolumetric contrac...

متن کامل

Effect of Underwater Ambient Noise on Quadraphase Phase-shift Keying Acoustic Sensor Network Links in Extremely Low Frequency Band

This study evaluates the impact of underwater ambient noise using seven real noise samples; Dolphin, Rain, Ferry, Sonar, Bubbles, Lightning, and Outboard Motor in three frequency ranges in extremely low frequency (ELF) band. The ELF band is the most significant bandwidth for underwater long-range communication. ELF band which is extended from 3 to 3000 Hz clearly, faces bandwidth limitation. Me...

متن کامل

Pulsed doppler echocardiographic measurement of beat-to-beat changes in stroke volume in dogs.

Measurement of stroke volume by pulsed Doppler echocardiography has not been validated against a reference method in vivo. We compared Doppler systolic frequency shift integrals with electromagnetic flowmeter stroke volume in seven open-chest dogs. A pulsed Doppler echocardiographic transducer was held on the aortic arch with the sample volume in the ascending aorta. Stroke volume was varied by...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013