Time points may also count in assessment of the difference between prescribed and delivered dose.
نویسنده
چکیده
Sir, I read with great interest the article by Lyndon et al. [1]. They analyzed data of a prospective trial [2] to investigate the difference between prescribed and delivered continuous renal replacement therapy (CRRT) doses and concluded that there was a large gap between the delivered and prescribed dose. This is important for interventional studies comparing intensive versus less intensive dose CRRT on the patients’ clinical outcome, because it is the actual delivered dose that determines the clinical outcome. However, one factor that the article did not take into account was the time point in which the comparison between prescribed and delivered dose was made. The rationale of this consideration is that the filter will become clogged over time, and the sieving coefficient of solute may be compromised; namely, the ratio of concentration of effluent urea nitrogen to blood urea nitrogen (BUN) is <1, resulting in a much more reduced delivered dose. Another phenomenon known as concentration polarization may also develop on the filter membrane during CRRT. It is a layer of protein fouling on the membrane that will lead to diffusive transport of solutes back into the blood pool, thereby further compromising the efficacy of solute clearance [3]. However, the impact of time on the delivered dose might be more pronounced in medium or large-sized molecules, and its impact on small-sized solutes, such as creatinine and BUN as used in the present study, is unknown. In the study, enrolled patients had their creatinine and urea nitrogen in blood and effluent fluid measured on a daily basis, and there would be several measurements of both urea nitrogen and creatinine for each filter, allowing calculation of delivered solute clearance at different time points. I do not know which set of measurements is used for the estimation of solute clearance. One strength of the study is the large sample size (165 patients) as compared with the study by Granado et al. [4] (52 patients). If time points can also be incorporated into the analysis, more information can be obtained with regard to the difference between the prescribed and delivered dose over time. By the way, there is a small error in Table 1 and Table 2, the unit of dose should be ‘mL/kg/h’, instead of ‘mg/kg/h’.
منابع مشابه
Verification of the Accuracy of the Delivered Dose in Pelvic and Breast Cancer Radiotherapy by in-vivo Semi-Conductor Dosimetry
Introduction: Delivering maximum dose to tumor and minimum dose to normal tissues is the most important goal in radiotherapy. According to ICRU, the maximum acceptable uncertainty in the delivered dose compared to the prescribed dose should be lower than 5%, and this is because of the relationship between absorbed dose, tumor control and normal tissue damage. Absorbed dose accuracy is investiga...
متن کاملAssessment of Dose Calculation Accuracy of TiGRT Treatment Planning System for Physical Wedged fields in Radiotherapy
Introduction Wedge modifiers are commonly applied in external beam radiotherapy to change the dose distribution corresponding to the body contour and to obtain a uniform dose distribution within the target volume. Since the radiation dose delivered to the target must be within ±5% of the prescribed dose, accurate dose calculation by a treatment planning system (TPS) is important. The objective ...
متن کاملThe Effect of Pregnancy Induced Hypertension on Complete Blood Count of Newborn
Background: Pregnancy induced hypertension is one of the most common causes of maternal and neonatal mortality and morbidity. New born delivered to mothers with hypertension are more liable for intrauterine growth retardation and may be delivered prematurely. We aimed to determine the effect of pregnancy-induced hypertension on complete blood count, gestational age and birth weight of newborn...
متن کاملAssessment the Effect of Kidney Internal Structure on Gamma Absorbed Dose of Radiopharmaceutical 111In-DTPA
Large quantities of radiopharmaceuticals prescribed for treatment and diagnosis are excreted through kidney. Therefore, radiation unwanted dose is created in kidney. As a result, exact calculation of prescribed radiopharmaceuticals amount is important. Monte Carlo method is used for simulation of radiation transport in body due to random nature of radiation. In this research, for the first time...
متن کاملارائه روش پرتودرمانی تطبیقی جدید تک ایزوسنتریک در پرتودرمانی خارجی دیواره سینه بیماران مستکتومی شده
Introduction and purpose: The aim of this study is introducing a new Mono-Isocentric Technique)MIT) for external radiotherapy of the chest wall in the mastectomy patients with 6MV photon beams and comparing this technique with the Dual-Isocentric Technique(DIT). Materials and methods: Data of 18 mastectomy patients having chest wall radiotherapy were used. The target tissue was divided into...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 27 2 شماره
صفحات -
تاریخ انتشار 2012