The bimodal jitter: a single fibre electromyographic finding.

نویسندگان

  • B Thiele
  • E Stålberg
چکیده

The jitter, obtained by SFEMG recordings, mainly reflects the neuromuscular transmission time variability and is usually Gaussian distributed. Here is reported the bimodal distribution of the interpotential intervals, the flip-flop phenomenon. Long flip-flop in cases of reinnervation may indicate alternatively continuous and saltatory nerve conduction. Short flip-flop in normal subjects may be due to muscle fibre interaction or nerve conduction irregularities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Regional curare for the reduction of the safety factor in human motor end-plates studied with single fibre electromyography.

A method employing six minutes of regional curarization with 0.5 mg D-tubocurarine and single fibre electromyographic measurements (SFEMG) was used in order to study the effect of an additional small dose of D-tubocurarine. The effect of the additional dose was most pronounced in terms of increased jitter, on motor end-plates with the initially highest jitter. The combination of regional curari...

متن کامل

Single fibre electromyographic jitter in multiple sclerosis.

Recent histological and electrophysiological reports have given evidence for peripheral nervous system (PNS) involvement in multiple sclerosis. We have applied the single fibre electromyography (SFEMG) technique to 15 patients with multiple sclerosis. Six patients had clearly abnormal jitter and two of these had previously undiagnosed coexistent peripheral neuropathy. A further five patients ha...

متن کامل

Transmission block in terminal nerve twigs: a single fibre electromyographic finding in man.

Single fibre electromyography has been performed in patients with partial nerve lesions, amyotrophic lateral sclerosis, progressive spinal muscle atrophy, muscular dystrophy, and distal hereditary myopathy. The recorded action potentials were often more complex than in the normal muscle due to increased fibre density in the motor unit and the individual spike components showed a large jitter an...

متن کامل

Automatically Measuring Neuromuscular Jitter

ii I hereby declare that I am the sole author of this thesis. This is a true copy of the thesis, including any required final revisions, as accepted by my examiners. I understand that my thesis may be made electronically available to the public. iii Abstract The analysis of electromyographic (EMG) signals detected during muscle contraction provides important information to aid in the diagnosis ...

متن کامل

Neuromuscular transmission in myasthenia gravis studied with single fibre electromyography.

Patients with myasthenia gravis have been investigated with single fibre electromyography. In all myasthenic muscles recordings were obtained where there was an increase of the jitter and occasional blocking of different degree of single fibre action potentials. The jitter is the variability at consecutive discharges in the time interval between action potentials from two muscle fibres from the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurology, neurosurgery, and psychiatry

دوره 37 4  شماره 

صفحات  -

تاریخ انتشار 1974