Catheter ablation of paroxysmal atrial fibrillation using a 3D mapping system.
نویسندگان
چکیده
BACKGROUND We treated paroxysmal recurrent atrial fibrillation (AF) with radiofrequency (RF) catheter ablation by creating long linear lesions in the atria. To achieve line continuity, a 3D electroanatomic nonfluoroscopic mapping system was used. METHODS AND RESULTS In 27 patients with recurrent AF, a catheter incorporating a passive magnetic field sensor was navigated in both atria to construct a 3D activation map. RF energy was delivered to create continuous linear lesions: 3 lines (intercaval, isthmic, and anteroseptal) in the right atrium and a long line encircling the pulmonary veins in the left atrium. After RF application, the atria were remapped to validate completeness of the block lines, demonstrated by late activation of the areas circumscribed by the lines. The mean procedure duration was 312+/-103 minutes (range, 187 to 495), with mean fluoroscopy time of 107+/-44 minutes (range, 32 to 185 minutes). No acute complications occurred, but 1 patient experienced early prolonged sinus pauses and received a pacemaker. During the first day, 17 patients (63%) had AF episodes, but at discharge, 25 patients were in sinus rhythm. After a follow-up of 6. 0 to 15.3 months (average, 10.5+/-3.0 months), 16 patients are asymptomatic, 3 have an almost complete disappearance of symptoms, 1 patient is improved, and 7 patients have their AF attacks unchanged. CONCLUSIONS Paroxysmal recurrent drug-refractory AF can be treated by RF catheter ablation. Creation of long continuous linear lesions necessary to compartmentalize the atria is facilitated by a nonfluoroscopic electroanatomic mapping system.
منابع مشابه
Intracardiac ECHO Integration with Three Dimensional Mapping: Role in AF Ablation.
Background: Catheter ablation of atrial fibrillation (AF) is typically guided by 3D mapping. This involves point-by-point reconstruction of the 3D virtual anatomy and may be time consuming and require substantial fluoroscopy exposure. Intracardiac echocardiography (ICE) affords real time imaging of the cardiac structures during mapping and ablation. Methods: Between February and May 2007, 15 pa...
متن کاملA systematic review of the effectiveness of catheter ablation NavX mapping system for treatment of the cardiac arrhythmia
Background: Catheter ablation is widely used for treatment of atrial fibrillation. The use of fluoroscopic and non-fluoroscopic mapping systems in catheter ablation is common. This study conducted to investigate the safety and effectiveness of Navx non-fluoroscopic mapping system. Methods : In this study, the appropriate electronic databases including Cochrane Library and Ovid Medline searc...
متن کاملNovel approaches for quantitative electrogram analysis for intraprocedural guidance for catheter ablation: A case of a patient with persistent atrial fibrillation
Purpose Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia that causes stroke affecting more than 2.3 million people in the US and is increasing in prevalence due to ageing population causing a new global epidemic. Catheter ablation with pulmonary vein isolation (PVI) to terminate AF is successful for paroxysmal AF but suffers limitations with persistent AF patients as cur...
متن کاملAF Sustained in Only a Small Area of SVC
A 66-year-old female was admitted to our hospital to undergo catheter ablation for symptomatic paroxysmal atrial fibrillation (AF). After pulmonary vein isolation was achieved by cryoballoon and adenosine triphosphate was injected to confirm the dormant conduction of the pulmonary veins, AF was induced. Sinus rhythm was restored by cardioversion, whereas AF was sustained only in the superior ve...
متن کاملComputed tomography model-based treatment of atrial fibrillation and atrial macro-re-entrant tachycardia
AIMS Accurate orientation within true three-dimensional (3D) anatomies is essential for the successful radiofrequency (RF) catheter ablation of atrial fibrillation (AF) and atrial macro-re-entrant tachycardia (MRT). In this prospective study, ablation of AF and MRT was performed exclusively using a pre-acquired and integrated computed tomography (CT) image for anatomical 3D orientation without ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 100 11 شماره
صفحات -