Finite element modeling of trabecular bone from multi-row detector CT imaging
نویسندگان
چکیده
ACKNOWLEDGMENTS First of all, I would like to give my most sincere thanks to my advisor Professor Punam K. and Ryan Amelon for their help on my research. In the end, I want to thank all the faculty, staff and students of The Iowa Institute for Biomedical Imaging and Electrical and Computer Engineering for their improving lectures and kind help. iii ABSTRACT The finite element method (FEM) has been widely applied to various medical imaging applications over the past two decades. The remarkable progress in high-resolutio n imaging techniques has allowed FEM to draw great research interests in computing trabecular bone (TB) stiffness from three-dimensional volumetric imaging. However, only a few results are available in literature on applying FEM to multi-row detector CT (MDCT) imaging due to the challenges posed by limited spatial resolution. The research presented here develops new methods to preserve TB structure connectivity and to generate high-quality mesh representation for FEM from relatively low resolution images available at MDCT imaging. Specifically, it introduced a space-variant hysteresis algorithm to threshold local trabecular structure that preserves structure connectivity. Also, mesh generation algorithms was applied to represent TB micro-architecture and mesh quality was compared with that generated by traditional methods. TB stiffness was computed using FEM simulation on micro-CT (µ-CT) and MDCT images of twenty two cadaveric specimens of distal tibia. Actual stiffness of those specimens were experimenta lly determined by mechanical testing and its correlation with computed stiffness was analyzed. The observed values of linear correlation (r 2) between actual bone stiffness and computed stiffness from µ-CT and MDCT imaging were 0.95 and 0.88, respectively. Also, reproducibility of the FEM-based computed bone stiffness was determined from repeat MDCT scans of cadaveric specimens and the observed intra-class correlation coeffic ie nt was a high value of 0.98. Experimental results demonstrate the feasibility of application of FEM with high sensitivity and reproducibility on MDCT imaging of TB at distal tibia under in vivo condition. iv PUBLIC ABSTRACT Over the past two decades, trabecular bone (TB) study has drawn research interests to determine bone quality, understand causes of diseases, and assess risks of fractures. The finite element method (FEM) is an advanced computer-aided method that computes stiffness and simulates behaviors of target object. With the remarkable progress of high-resolution imaging techniques, FEM has been widely applied in TB study. However, only a few research focuses on FEM application on multi-row detector CT …
منابع مشابه
(micro-CT) imaging, and voxel-based finite element modeling to detect trabecular bone microdamage and microfracture and estimate the associated microstructural stresses and strains. METHODS Cylindrical reduced-section specimens were prepared from skeletally mature bovine proximal tibial trabecular bone
INTRODUCTION The onset of trabecular bone damage is a local phenomenon, governed by tissue-level material properties, and architecture at the initiation site. Different modes of microfracture (bending, buckling, and shearing) and microdamage (single, parallel, and cross-hatched cracks) can occur [1]. The initiation of bone damage can lead to two scenarios. In the first case, normal repair proce...
متن کاملOsteoporosis imaging: effects of bone preservation on MDCT-based trabecular bone microstructure parameters and finite element models
BACKGROUND Osteoporosis is defined as a skeletal disorder characterized by compromised bone strength due to a reduction of bone mass and deterioration of bone microstructure predisposing an individual to an increased risk of fracture. Trabecular bone microstructure analysis and finite element models (FEM) have shown to improve the prediction of bone strength beyond bone mineral density (BMD) me...
متن کاملMultiplanar and 3D imaging of the central airways: comparison of image quality and radiation dose of single-detector row CT and multi-detector row CT at differing tube currents in dogs.
PURPOSE To compare in an animal model the image quality of multiplanar reformation and three-dimensional (3D) reconstruction images of the central airways by using single-detector row computed tomography (CT) and multi-detector row CT at varied tube currents and to compare radiation dose. MATERIALS AND METHODS Five dogs each underwent five consecutive helical CT examinations (one single-detec...
متن کاملWomen with anorexia nervosa: finite element and trabecular structure analysis by using flat-panel volume CT.
PURPOSE To use finite element modeling based on flat-panel volume computed tomography (CT) and bone mineral density (BMD) provided by dual-energy x-ray absorptiometry (DXA) to compare bone failure load, stiffness, and trabecular structure in women with anorexia nervosa (AN) and age-matched normal-weight control subjects. MATERIALS AND METHODS The study was approved by the institutional review...
متن کاملInfluence of Trabecular Bone on Peri-Implant Stress and Strain Based on Micro-CT Finite Element Modeling of Beagle Dog
The objective of this investigation is to analyze the influence of trabecular microstructure modeling on the biomechanical distribution of the implant-bone interface. Two three-dimensional finite element mandible models, one with trabecular microstructure (a refined model) and one with macrostructure (a simplified model), were built. The values of equivalent stress at the implant-bone interface...