Impact on rectal dose from the use of a prostate immobilization and rectal localization device for patients receiving dose escalated 3D conformal radiation therapy.
نویسندگان
چکیده
PURPOSE When >25% of the rectum is irradiated to > or = 70 Gy, the risk of developing Grade 2 or higher rectal complications is significantly increased. This study evaluates the impact on dose to the rectum from the use of an intrarectal (IR) balloon device, previously shown to immobilize the prostate gland and localize the rectum, in patients receiving dose escalated 3-dimentional (3D) conformal radiation therapy. MATERIALS AND METHODS From July 2001 through February 2003, 28 consecutive patients with prostate cancer underwent computerized tomography-based simulation with and without the IR balloon in place. Treatment planning was performed for three clinical paradigms in which the IR balloon was not used at all (0 Gy), used during the cone-down for 15 treatments (28.35 Gy), or used for the entire course of 40 treatments (75.6 Gy). The three plans were compared for differences in the percent of rectum receiving >70 Gy. RESULTS Dose volume histogram (DVH) analysis revealed that the median(range) of percent rectal volume exceeding 70 Gy was 25% (12.7-41.5%), 7.5% (0.9-19.5%), and 3.6% (0-8.7%) for patients in whom the IR balloon was used for 0, 15, and 40 treatments, respectively. The percent of rectum exceeding 70 Gy was significantly different for all treatment plan comparisons (P < 0.0001). CONCLUSIONS Grade 2 or higher rectal toxicity may be minimized during dose escalated 3D conformal radiation therapy through the use of an IR balloon during the 3-week cone down portion of an 8-week treatment course.
منابع مشابه
The effect of Rectal Retractor, a rectal protector on rectal dose in radical prostate radiotherapy
Introduction: The close proximity of the rectum tissue to the prostate gland results in rectal toxicity during prostate radiotherapy. Rectal Retractor (RR) is a rectal displacement technique that inserts into the rectum, as a result, the lateral and dorsal part of the rectal wall push away from high dose areas. The aim of this study was to investigate the dosimetric consequence...
متن کامل3 D conformal external beam radiation therapy for prostate carcinoma : an experiment of Instituto do
OBJECTIVE: To report the outcomes of 3D conformal radiation therapy for prostate cancer in a single institution. MATERIALS AND METHODS: From July 1997 to January 2002, 285 consecutive patients with prostate cancer were submitted to 3D conformal radiation therapy receiving a median dose of 7920 cGy to the prostate, and were retrospectively evaluated. The patients distribution according to the le...
متن کاملComparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy
Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...
متن کاملAssessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer
Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...
متن کاملThe effects of volumetric changes on radiation doses of the rectum and bladder during radiotherapy in patients with prostate cancer
Background: In prostate radiotherapy, changes in the volume of the bladder and rectum can influence dose delivery. In this study, cone-beam computerised tomography (CBCT) imaging was used to assess volumetric, and corresponding radiation dosimetric changes, for the bladder and rectum in patients with prostate cancer treated using VMAT. Materials and Methods: Treatment planning computed tomograp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Urologic oncology
دوره 22 3 شماره
صفحات -
تاریخ انتشار 2004