Central and peripheral intraocular pressure measured by a rebound tonometer
نویسندگان
چکیده
PURPOSE We investigated at which corneal region the intraocular pressure as measured by the Icare(®) rebound tonometer (Finland Oy, Espoo, Finland) (hereinafter referred to as IC) was closest to the intraocular pressure as measured by the Goldmann applanation tonometer (hereinafter referred to as GT). We also investigated which parameters would be best for preparing the most suitable model for predicting GT. METHODS A total of 102 normal eyes in 102 subjects were enrolled. IC measurements were carried out at the central, superior, inferior, temporal, and nasal regions of the cornea (ICC, ICS, ICI, ICT, and ICN, respectively), followed by GT calculations. Differences between GT and IC were analyzed using the Bland-Altman method. Stepwise multiple regression analysis was performed using GT as the objective variable, and age, laterality of eye, spherical equivalent refractive error, corneal radius, axial length, central corneal thickness, GT, ICC, ICS, ICI, ICT, and ICN as the explanatory variables. RESULTS IC was higher than GT at all of the corneal regions, but the region with the least bias was ICC, followed by ICT. In the multiple regression analysis, the following prediction formula was calculated: GT = (0.445 × ICC) + (0.198 × ICN) + 3.022. When ICC was excluded from the explanatory variables, ICT had the highest partial correlation coefficient with GT. CONCLUSION ICC was closest to GT, but GT could be explained better by adding ICN to the prediction model. Moreover, in instances where ICC cannot be calculated or where reliability is clearly poor due to abnormal ocular rigidity, ICT was the closest to GT measured in the central corneal region.
منابع مشابه
Age differences in central and peripheral intraocular pressure using a rebound tonometer.
AIM To evaluate the influence of age on the measurements and relationships among central and peripheral intraocular pressure (IOP) readings taken with a rebound tonometer. METHODS The IOPs were measured using the ICare rebound tonometer on the right eyes of 217 patients (88 men and 129 women) aged 18-85 years (mean 45.9 (SD 19.8) years), at the centre and at 2 mm from the nasal and temporal l...
متن کاملComparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.
BACKGROUND To compare the intraocular pressure readings obtained with the iCare rebound tonometer and the 7CR non-contact tonometer with those measured by Goldmann applanation tonometry in treated glaucoma patients. DESIGN A prospective, cross-sectional study was conducted in a private tertiary glaucoma clinic. PARTICIPANTS OR SAMPLES One hundred nine (54 males : 55 females) patients includ...
متن کاملIntraocular pressure measurement over soft contact lens by rebound tonometer: a comparative study.
AIM To evaluate the intraocular pressure (IOP) measurements by Icare rebound tonometer over a contact lens in comparison with Goldmann applanation tonometry (GAT). METHODS Fifty patients using contact lens were included in this study. One of the eyes of the patients was selected randomly and their IOP were measured by rebound tonometer with and without contact lens (RTCL, RT respectively) and...
متن کاملDoes Rebound Tonometry Probe Misalignment Modify Intraocular Pressure Measurements in Human Eyes?
Purpose. To examine the influence of positional misalignments on intraocular pressure (IOP) measurement with a rebound tonometer. Methods. Using the iCare rebound tonometer, IOP readings were taken from the right eye of 36 healthy subjects at the central corneal apex (CC) and compared to IOP measures using the Goldmann applanation tonometer (GAT). Using a bespoke rig, iCare IOP readings were al...
متن کاملEvaluation of the ICare rebound tonometer as a home intraocular pressure monitoring device.
PURPOSE (a) To investigate whether the ICare rebound tonometer can provide accurate measurements of intraocular pressure (IOP) in the hands of an inexperienced user compared with ICare measurements and Goldmann tonometry by a trained technician and (b) to assess the intrauser reproducibility of IOP measurements and the learning curve among patients using the ICare rebound tonometer. METHODS A...