Determinants and Characteristics of Bruch's Membrane Opening and Bruch's Membrane Opening-Minimum Rim Width in a Normal Japanese Population.
نویسندگان
چکیده
Purpose To identify determinants of Bruch's membrane opening (BMO), and BMO-minimum rim width (BMO-MRW) and circumpapillary retinal nerve fiber layer thickness (RNFLT) centered on BMO center and characterize these parameters in a normal Japanese population. Methods Spectral-domain optical coherence tomography images of optic nerve head and circumpapillary and macular retina were obtained in 258 eyes of 258 normal Japanese with mean (standard deviation) age of 51.7 (18.2) years. BMO area, BMO-MRW, RNFLT (measured with a 3.5-mm-diameter circle scan) were all acquired and analyzed relative to the eye-specific fovea to BMO (FoBMO) axis. One randomly selected eye of each subject was analyzed. Multiple regression analysis was used to identify determinants to the parameters. Results BMO area, global BMO-MRW, RNFLT, and FoBMO angle averaged 2.06 (0.45) mm2, 305.5 (50.0) μm, 101.8 (9.6) μm, and -7.8° (3.8°), respectively. There was a modest correlation between global BMO-MRW and RNFLT (r = 0.337; P < 0.001), while the sectorwise correlations were highest in the superior-temporal sector (r = 0.500; P < 0.001) and lowest in the nasal sector (r = 0.117; P = 0.063). Global BMO-MRW and RNFLT declined with age at -1.04 μm/y (P < 0.001) and -0.12 μm/y (P = 0.001), and the former correlated negatively (P = 0.001) and the latter positively (P < 0.001) with BMO area after adjustment for other factors (R2 = 0.191 and 0.272, respectively). BMO area correlated positively with axial length (P = 0.023) and negatively with age (P < 0.001) (R2 = 0.157). Conclusions BMO-MRW and RNFLT declined with age with a difference between them in their relationship to BMO area. BMO area positively correlated with axial length and negatively with age.
منابع مشابه
Bruch's Membrane Opening Minimum Rim Width Measurement with SD-OCT: A Method to Correct for the Opening Size of Bruch's Membrane
A precise evaluation of the retinal nerve fiber layer thickness (RNFLT) is key for diagnosing and monitoring glaucoma. The Bruch's membrane opening minimum rim width (BMO-MRW) has been proposed as a reproducible assessment of the optic nerve. The BMO-MRW measures the minimum distance from the BMO to the internal limiting membrane. We propose an approach to correct the BMO-MRW using the BMO size...
متن کاملStructure-Function Relationships in Perimetric Glaucoma: Comparison of Minimum-Rim Width and Retinal Nerve Fiber Layer Parameters
Purpose To test the hypotheses that: (1) structure-function (SF) relationships between visual fields (VF) and Bruch's membrane opening-based minimum rim width (BMO-MRW) measurements are superior to those for peripapillary retinal nerve fiber layer (pRNFL) in perimetric glaucoma; (2) BMO-MRW measurements may extend the utility of structural measurement across the range of glaucoma severity; and ...
متن کاملStructure-Function Relationship Between Bruch's Membrane Opening-Based Optic Nerve Head Parameters and Visual Field Defects in Glaucoma.
PURPOSE This study was performed to evaluate the structure-function relationship between Bruch's membrane opening (BMO) parameters of the optic nerve head (ONH) and visual field (VF) sensitivity. METHODS Forty-six right eyes of 46 patients with open-angle glaucoma (OAG) in the patient group and 12 right eyes in the control group were included. Standard automated perimetry (SAP) and spectral-d...
متن کاملThe new Bruch’s membrane opening – minimum rim width classification improves optical coherence tomography specificity in tilted discs
BACKGROUND AND OBJECTIVE To investigate and compare the false-positive (FP) diagnostic classification of the Bruch's membrane opening - minimum rim width (BMO-MRW) and retinal nerve fiber layer (RNFL) thickness in healthy eyes with tilted optic disc. MATERIALS AND METHODS Fifty healthy eyes of 30 participants with tilted optic disc underwent BMO-MRW and RNFL scanning using Spectralis and macu...
متن کاملThe Impact of Lens Opacity on SD-OCT Retinal Nerve Fiber Layer and Bruch's Membrane Opening Measurements Using the Anatomical Positioning System (APS).
Purpose To evaluate the impact of lens opacity on retinal nerve fiber layer thickness (RNFLT) and Bruch's membrane opening (BMO) measurements. Methods Fifty-nine randomly selected patients without any other relevant ocular pathology undergoing elective routine cataract surgery in two specialized eye clinics were enrolled. RNFLT, BMO area, and BMO minimum rim width (BMO-MRW) were assessed with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 58 10 شماره
صفحات -