[Safety and effectiveness of single-lead VDD pacing].

نویسندگان

  • Maruan C Chabbar Boudet
  • Antonella Lukic
  • José G Galache Osuna
  • Jesús De Juan Montiel
  • Eduardo Cay Diarte
  • José A Diarte de Miguel
  • Luis J Placer Peralta
چکیده

INTRODUCTION AND OBJECTIVES Single-lead VDD pacing provides the physiological benefits of atrioventricular synchrony with the convenience of a single-lead system. However, concern remains about the method's safety and effectiveness. METHOD In total, 700 patients with single-lead VDD pacemakers were evaluated retrospectively. The following parameters were recorded: age, sex, etiology, the symptoms and electrocardiographic diagnosis that justified pacemaker implantation, the venous access route used for implantation, atrial sensing at implantation, atrial undersensing at follow-up, the occurrence of supraventricular tachyarrhythmias, and final pacing mode. RESULTS Third-degree atrioventricular block was the main indication for pacemaker implantation (66.4%). The most commonly used venous access route was via the right cephalic vein (49.1%). At implantation, the mean atrial signal was 1.8 (4 1.15) mV. During follow-up, significant atrial undersensing occurred in 7.7% of patients; in 1.9%, it could not be corrected by device reprogramming. Uncontrollable supraventricular arrhythmias were observed in 6.4% of patients. Symptomatic sinus node disease was rare. By the end of follow-up, 91.4% of patients were still on VDD pacing, while, in 8.3%, the pacemaker had to be reprogrammed to the VVI mode. Only 0.3% required atrial lead implantation for DDD pacing. Left-side venous access during implantation was a independent predictora of atrial undersensing at follow-up. Low values of atrial detection at implant did not reach statistical signification although it showed a remarkable trend. CONCLUSIONS Single-lead VDD pacing seems to be safe and effective when appropriately indicated. Our findings are consistent with those of previously published studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrospective analysis of mode survival, reliability of atrial sensing and incidence of atrial tachyarrhythmias in 307 single-lead VDD pacemaker patients.

AIMS The aim of this retrospective analysis was to investigate VDD mode survival, development of atrial tachyarrhythmias (AT), and long-term atrial sensing performance of VDD pacing systems. METHODS AND RESULTS We implanted single-lead VDD pacemakers in patients with isolated atrioventricular block and performed a retrospective analysis of 307 patients who had their devices implanted between ...

متن کامل

Immediate and mid-term safety and efficacy of single lead VDD pacemakers for patients with atrioventricular block and normal sinus node function--a single centre experience.

INTRODUCTION Single lead atrial synchronous ventricular pacing (VDD) is increasingly being used in place of conventional dual chamber pacing (DDD) for patients with atrioventricular block and preserved sinus node function. Compared to the latter, VDD pacemakers provide similar haemodynamic benefits derived from atrial synchronous pacing, with the added benefit of an easier implant procedure. ...

متن کامل

Cost-effectiveness of dual-chamber pacemaker therapy: does single lead VDD pacing reduce treatment costs of atrioventricular block?

AIMS Implantation of single-lead VDD pacemakers is an established alternative to DDD pacing in patients with atrioventricular block. This study compares the long-term costs of both systems. METHODS AND RESULTS Three hundred and sixty patients with atrioventricular block received VDD or DDD pacemakers in alternating order. Primary costs of implantation included: devices, leads and operation ma...

متن کامل

Dual chamber cardiac pacing in children: Single chamber pacing dual chamber sensing cardiac pacemaker or dual chamber pacing and sensing cardiac pacemaker?

BACKGROUND Dual chamber pacemakers (single chamber pacing dual chamber sensing cardiac pacemaker (VDD) and dual chamber pacing and sensing cardiac pacemaker (DDD)) are being used frequently in children and adolescents. The aim of this study was to verify the safety and performance of the VDD and DDD pacing systems, and to evaluate the differences between two pacing modes with regard to atrial s...

متن کامل

Long-term follow-up of single-lead VDD pacing.

Long-term outcomes of single-lead VDD pacing were studied retrospectively and partly prospectively. Records were analysed of 81 patients out of 133 in whom a single-lead VDD pacemaker was implanted between January 1993 and December 1997 and who attended a follow-up clinic more than two years after the implant. Forty-eight of them attended a prospective follow-up 54 +/- 15 months after the impla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 59 9  شماره 

صفحات  -

تاریخ انتشار 2006