Secondary fluorescence in electron probe microanalysis of material couples
نویسندگان
چکیده
We describe a semi-analytical method for the fast calculation of secondary fluorescence in electron probe microanalysis of material couples. The calculation includes contributions from primary K-, Land M-shell characteristic x-rays and bremsstrahlung photons. The required physical interaction parameters (subshell partial cross sections, attenuation coefficients, etc) are extracted from the database of the Monte Carlo simulation code system PENELOPE. The calculation makes use of the intensities of primary photons released in interactions of beam electrons and secondary electrons. Since these intensities are not readily available and do not allow analytical calculation, they are generated from short Monte Carlo simulation runs. The reliability of the proposed calculation method has been assessed by comparing calculated, distance-dependent k-ratios with experimental data available in the literature and with results from simulations with PENELOPE. Numerical results are found to be in close agreement with both simulated and experimental data. (Some figures may appear in colour only in the online journal)
منابع مشابه
Monte Carlo simulation of Nb Ka secondary fluorescence in EPMA: comparison of PENELOPE simulations with experimental results
Secondary fluorescence across phase boundaries is a difficult problem encountered in several electron probe microanalysis (EPMA) situations: diffusion couples; small phases enclosed in a larger phases; eutectic intergrowths; and thin films. In some cases, it is possible to construct nondiffused couples and to measure the amount of secondary fluorescence across the phase boundary, but in most ca...
متن کاملNumerical correction for secondary fluorescence across phase boundaries in EPMA
A fast calculation method to compute secondary fluorescence near phase boundaries in electron probe microanalysis is described. Secondary fluorescence intensities are calculated by numerically integrating the equations that describe the emission of fluorescence by photoelectric absorption of primary X-rays (characteristic and bremsstrahlung) from a couple of two semi-infinite, adjacent material...
متن کاملMonte Carlo Simulation of Characteristic Secondary Fluorescence in Electron Probe Microanalysis of Homogeneous Samples Using the Splitting Technique.
Electron probe microanalysis (EPMA) is based on the comparison of characteristic intensities induced by monoenergetic electrons. When the electron beam ionizes inner atomic shells and these ionizations cause the emission of characteristic X-rays, secondary fluorescence can occur, originating from ionizations induced by X-ray photons produced by the primary electron interactions. As detectors ar...
متن کاملIn Situ Analysis of Gut Residue of Corophium Volutator (Pallas) by Electron Probe Microanalysis after Exposure to Barytes Spiked Sediments
Corophium volutator (Pallas) has been recommended by the paris Commission as one of the standard species for testing chemical used in offshore oil and gas exploration/production. In the present study, gut contents of Corophium volutator have been analysed by electron probe microanalysis (EPMA) for BaSO4 and other heavy metal impurities after exposure tto spiked sediments followin...
متن کاملElectron Probe Microanalysis (EPMA)
An electron microprobe is an electron microscope designed for the non-destructive x-ray microanalysis and imaging of solid materials. It is essentially a hybrid instrument combining the capabilities of both the scanning electron microscope (SEM) and an x-ray fluorescence spectrometer (XRF), with the added features of fine-spot focusing (~ 1 micrometer), optical microscope imaging, and precision...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012