New results from an extensive aging test on bakelite Resistive Plate

نویسندگان

  • G. Carboni
  • G. Collazuol
  • S. De Capua
  • D. Domenici
  • G. Ganis
  • R. Messi
  • G. Passaleva
  • E. Santovetti
  • M. Veltri
چکیده

We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single–gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC under high particle flux conditions, we have periodically measured the electrode resistance R of the two RPC prototypes over three years: we observe a large spontaneous increase of R with time, from the initial value of about 2 MΩ to more than 250 MΩ. A corresponding degradation of the RPC rate capabilities, from more than 3 kHz/cm 2 to less than 0.15 kHz/cm 2 is also found.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Final results from an extensive ageing test of bakelite Resistive Plate Chambers

We present the final results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two bakelite Resistive Plate Chambers (RPC) detectors. With a method based on a model describing the behaviour of an RPC under high particle flux conditions, we have periodically measured the electrode resistivity r of the two RPC prototypes over 3 years. We observed a large spontaneous ...

متن کامل

An extensive aging study of bakelite Resistive Plate Chambers

We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility, on two bakelite Resistive Plate Chambers (RPC) detectors. With a method based on a model describing the behavior of an RPC exposed to a large particle flux, we have periodically measured the electrode resistivity r of the two detectors over 3 years. We observed a large increase of r with time...

متن کامل

. in s - de t ] 2 1 Fe b 20 03 1 New results from an extensive aging test on bakelite Resistive Plate

We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single–gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC under high particle flux conditions, we have periodically measured the electrode resistance R of the two RPC prototypes over three years: we observe a large s...

متن کامل

A new surface treatment for the prototype RPCs of the BESIII spectrometer

The prototype resistive plate chambers (RPCs) for the BESIII spectrometer were constructed by using resistive electrodes made from a special type of phenolic paper laminates developed by us. The surface quality of these laminates is superior to other bakelite plates that have been used to construct RPCs elsewhere. A method for adjusting the resistivety of these laminates was also developed. Ext...

متن کامل

Beam Test Results on Resistive Plate Chambers for the CMS Experiment

Resistive Plate Chambers were tested in a muon and a pion beam to study the performances at different running conditions. Results on a first chamber built without the linseed oil treatment of the bakelite surfaces are presented together with an evaluation of the local effects due the spacers. These results are extrapolated to the conditions expected at LHC.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003