B-value dependence of DTI quantitation and sensitivity in detecting neural tissue changes
نویسندگان
چکیده
Recently, remarkable success has been demonstrated in using MR diffusion tensor imaging (DTI) to characterize white matter. Water diffusion in complex biological tissue microstructure is not a free or Gaussian process but is hindered and restricted, thus contradicting the basic assumption in conventional DTI that diffusion weighted signal decays with b-value in a monoexponential manner. Nevertheless, DTI by far is still the fastest and most robust protocol in routine research and clinical settings. To assess the b-value dependence of DTI indices and evaluate their sensitivities in detecting neural tissues changes, in vivo DTI data acquired from rat brains at postnatal day 13, 21 and 120 with different b-values (0.5-2.5 ms/microm(2)) and 30 gradient directions were analyzed. Results showed that the mean and directional diffusivities consistently decreased with b-value in both white and gray matters. The sensitivity of axial diffusivity (lambda(//)) in monitoring brain maturation generally decreased with b-value whereas that of radial diffusivity (lambda( perpendicular)) increased. FA generally varied less with b-value but in a manner dependent of the age and tissue type. Analysis also revealed that the FA sensitivity in detecting specific tissue changes was affected by b-value. These experimental findings confirmed the crucial effect of b-value on quantitative DTI in monitoring neural tissue alterations. They suggested that the choice of b-value in conventional DTI acquisition can be optimized for detecting neural tissue changes but shall depend on the specific tissue type and its changes or pathologies targeted, and caution must be taken in interpreting DTI indices.
منابع مشابه
Effect of cerebrovascular changes on brain DTI quantitation: a hypercapnia study.
Quantitative diffusion tensor imaging (DTI) offers a valuable tool to probe the microstructural changes in neural tissues in vivo, where absolute quantitation accuracy and reproducibility are essential. It has been long recognized that measurement of apparent diffusion coefficient (ADC) using DTI could be influenced by the presence of water molecules in cerebrovasculature. However, little is kn...
متن کاملNormal white matter development from infancy to adulthood: comparing diffusion tensor and high b value diffusion weighted MR images.
PURPOSE To evaluate the sensitivity of high b value diffusion weight magnetic resonance imaging (DWI) in detecting normal white matter maturation, compare it to conventional diffusion tensor imaging (DTI), and to obtain normative quantitative data using this method. MATERIALS AND METHODS High b value DWI (b(max) = 6000 sec/mm(2)) using q-space analysis and conventional DTI (b = 1000 sec/mm(2)...
متن کاملDetection of brain maturation - DTI with different B-values versus diffusion kurtosis imaging
Introduction DTI offers an unprecedented capability to probe tissue microstructure in vivo and non-invasively. However, DTI indices obtained from different b-values may probe different information regarding the complex diffusion processes in vivo. The non-monoexponential DW signal decay with b-value is largely attributed to the diffusion restriction due to underlying cellular microstructures. C...
متن کاملThe Benefits and implementations of Diffusion tensor imaging and Neural Fiber Tractography in Brain Surgery
Background and Aim: The methods for detecting brain activation with fMRI, MRI provides a way to measure the anatomical connections which enable lightning-fast communication among neurons that specialize in different kinds of brain functions. Diffusion tensor imaging is able to measure the direction of bundles of the axonal fibers which are all aligned. Besides mapping white matter fiber tracts,...
متن کاملTitle The effects of hypercapnia on DTI quantification in anesthetized rat brain
Diffusion Tensor Imaging (DTI) offers a valuable in vivo tool to characterize water diffusion behavior in biological tissues, particularly brain tissues. The accuracy of DTI derived parameters can directly affect the interpretation of underlying microstructures, physiology or pathologies. It is anticipated that measurement of apparent diffusion coefficient (ADC) using DTI could be influenced an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 49 3 شماره
صفحات -
تاریخ انتشار 2010