With use of dental implants on the rise, there is also a tandem increase in the number of implant fracture reports. To the end of investigating the stress occurring in implants, elasticity and plasticity analyses were performed using the finite element method. The following results were obtained: (1) With one-piece type of implants of 3.3 mm diameter, elasticity analysis showed that after applying 500 N in a 45-degree direction, stress exceeding 500 MPa which is the proof stress of grade 4 pure titanium - occurred. This suggested the possibility of fatigue destruction due to abnormal occlusal force, such as during bruxism. (2) With two-piece type of implants that can tolerate vertical loading of 5,000 N, plasticity analysis suggested the possibility of screw area fracture after applying 500 N in a 45-degree direction. (3) On the combined use of an abutment and a fixture from different manufacturers, fracture destruction of even Ti-6Al-4V, which has a high degree of strength, was predicted.
منابع مشابه
Effect of Abutment Angulation and Material on Stress and Strain Distributions in Premaxillary Bone: A Three-Dimensional Finite Element Analysis
Background and Aim: Dental implants with angled abutments are often inserted in the anterior maxillary region due to the status of the residual ridge and aesthetic considerations. The purpose of this study was to assess stress and strain distributions in the premaxillary bone around dental implants by means of finite element analysis (FEA). Materials and Methods: Four three-dimensional (3D) fi...
متن کاملA New Stress Based Approach for Nonlinear Finite Element Analysis
This article demonstrates a new approach for nonlinear finite element analysis. The methodology is very suitable and gives very accurate results in linear as well as in nonlinear range of the material behavior. Proposed methodology can be regarded as stress based finite element analysis as it is required to define the stress distribution within the structural body with structural idealization a...
متن کاملEvaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method
longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...
متن کاملImmediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis
Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis Dr. A. Fazel * - Dr. SH. A. Alai ** - Dr. M. Rismanchian *** *Associate Professor of Prosthodontics Dept., Faculty of Dentistry and Dental Research Center, Tehran University / Medical Sciences. **Assistant Professor of Prosthodontics Dept., Faculty of...
متن کاملNonlinear Finite Element Analysis of Thermoelastic Stresses of FGM Rotating Disk Considering Temperature-Dependency of Material Properties
In the present paper, nonlinear radial and hoop thermoelastic stresses analysis of a disk made of FGMs material is investigated. According to this purpose, finite element method is used. In the present method, second-order one-dimensional element (with three node points) is proposed. The geometrical and stress boundary conditions are defined in the state of non-existence of external pressure an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Dental materials journal
دوره 27 4 شماره
صفحات -
تاریخ انتشار 2008