Transient High-temperature Stress Relaxation of Prestressing Tendons in Unbonded Construction

نویسندگان

  • J. Gales
  • L. A. Bisby
  • C. MacDougall
  • K. MacLean
چکیده

Unbonded post-tensioned (UPT) flat plate concrete slabs are popular for modern continuous multiple bay floor assemblies due to economic and sustainability benefits (reductions in slab thickness and building selfweight) and structural advantages (decreased deflections over larger spans). Only limited research has been conducted on the performance of UPT flat plate slabs under fire conditions, yet the inherent fire endurance of these systems is sometimes quoted as a benefit of this type of construction. One concern for these structures in fire is that high temperature stress relaxation of the unbonded prestressed reinforcement may cause considerable and irrecoverable prestress loss, with subsequent structural consequences. This paper uses a computational model which has been developed to predict the transient high temperature stress relaxation (i.e., prestress loss) for typical UPT multiple span flat plate slabs in fire, to study the potential prestress relaxation behaviour under various plausible temperature conditions as might occur during exposure to a standard fire. The model is validated using experimental data from relaxation tests performed on locally heated unbonded seven-wire prestressing stand. The initial prestress level, concrete cover to the prestressed reinforcement, and ratio of heated length to overall tendon length are varied to investigate the potential implications for prestress loss, and subsequently for flexural and punching shear capacity. The results highlight the need for particular care in the construction of UPT slabs to ensure adequate concrete cover for structural fire safety.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unbonded Post Tensioned Concrete Slabs in Fire – Part II – Modelling Tendon Response and the Consequences of Localized Heating

This is Part II of a two part paper dealing with the current state of knowledge of the fire-safe structural design and construction of unbonded post-tensioned (UPT) flat plate concrete structures. Part I provided detailed results of nineteen transient high temperature stress relaxation tests on restrained UPT tendons of realistic length and parabolic longitudinal profiles. Experimentation ident...

متن کامل

Ultimate Unbonded Tendon Stress in CFRP Strengthened Post-Tensioned Indeterminate I-Beams Cast with HSCs

Based on the bending experiment for two-span continuous post-tension beams with unbounded tendons and externally applied CFRP sheets, the analysis of the stress increment of unbonded tendons is monitored in the loading process. Since self-compacting concrete (SCC) is a suitable innovation,, understanding the implementation of this type of concrete on the ultimate unbonded tendon stress is criti...

متن کامل

Feasibility Study of Measuring the Stress in Prestressing Tendons Using Induced Magnetic Field

This paper investigated experimentally the feasibility of the method to estimate the stress in the prestressing tendons of prestressed concrete bridges using the magnetic field induced by a moving electromagnet. This method is based on the Villari effect in which the magnetic permeability of prestressing tendons changes when subjected to a mechanical stress. The test results show high linearity...

متن کامل

Unbonded Post Tensioned Concrete in Fire: A Review of Data from Furnace Tests and Real Fires

The fire-safe design of concrete structures which incorporate post-tensioned prestressing tendons has recently been the subject of debate within the structural engineering community, particularly when unbonded post-tensioned (UPT) prestressing tendons are used. Despite several studies aimed at furthering our understanding of the response of UPT concrete structures in fire, many aspects of their...

متن کامل

Ultimate Tendon Stress in CFRP Strengthened Unbounded HSC Post-Tensioned Continuous I-Beams

The use of unbounded tendons is common in prestressed concrete structures and evaluation of the stress increase in unbonded tendons at ultimate flexural strength of such structure has posed a great challenge over the years. Based on the bending experiment for two-span continuous post-tension beams with unbounded tendons and externally applied CFRP sheets, the monitoring of the stress increment ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009