Automated method for L-carnitine determination.
نویسندگان
چکیده
Because of renewed interest in a possible connection between carnitine, lipid disorders, and myopathy, an automated method of analysis is desirable. Deproteinization of serum by use of membrane filter cones and automated assay with a bichromatic analyzer (the ABA-100) substantially increases efficiency without sacrificing the specificity and accuracy of the original manual enzymatic method. The described procedure allows for analysis of 80 speciments a day and is thus suitable for screening of selected populations. Normal values found in blood sera of adults were in the range of 25.0-73.8 mu mol/liter and the method has sufficient sensitivity to accurately measure concentrations as small as 10 mu mol/liter.
منابع مشابه
Determination of free and total carnitine with a random-access chemistry analyzer.
Carnitine deficiency presents as a major problem in fatty acid oxidation. The use of a plasma carnitine assay can rapidly help to describe this deficiency. The method we describe here requires two simple steps of sample preparation, followed by automated analysis with the Beckman Synchron CX4 random-access chemistry analyzer. The goal of this method development was to reduce the cost of analysi...
متن کاملAutomation of a spectrophotometric method for measuring L -carnitine in human blood serum
A spectrometric method for the determination of L-carnitine has been developed based on the reaction of the 5,5' dithiobis-(2-nitrobenzoic) acid (DTNB) and adapted to a Technicon RA-2000 automatic analyser Química Farmacéutica Bayer, S.A.). The detection limit of the method is 13.2 mumol/l, with a measurement interval ranging from 30 to 320 mumoll1. Imprecision and accuracy are good even at lev...
متن کاملCarnitine determination by an enzymatic cycling method with carnitine dehydrogenase.
We describe a highly sensitive and specific method for determining L-carnitine in serum by use of carnitine dehydrogenase (EC 1.1.1.108). The method involves a new enzymatic cycling technique with NADH, thio-NAD+, and carnitine dehydrogenase, and measures the increase of absorbance at 415 nm of thio-NADH produced at 37 degrees C during the reaction: [formula: see text] The calibration curve for...
متن کاملAnalytical approaches to determination of carnitine in biological materials, foods and dietary supplements.
l-Carnitine is a vitamin-like amino acid derivative, which is an essential factor in fatty acid metabolism as acyltransferase cofactor and in energy production processes, such as interconversion in the mechanisms of regulation of cetogenesis and termogenesis, and it is also used in the therapy of primary and secondary deficiency, and in other diseases. The determination of carnitine and acyl-ca...
متن کاملFluorometric determination of carnitine in serum with immobilized carnitine dehydrogenase and diaphorase.
A fluorometric flow-injection method for determining carnitine with use of immobilized enzymes carnitine dehydrogenase (EC 1.1.1.108) and diaphorase (EC 1.8.1.4) was developed and applied to the assay of carnitine in serum of patients treated with valproic acid. After fractionation and hydrolysis of carnitines in serum samples by perchloric acid and potassium hydroxide, liberated carnitine was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 22 10 شماره
صفحات -
تاریخ انتشار 1976