Right axillary and femoral artery perfusion with mild hypothermia for aortic arch replacement

نویسندگان

  • Jige Guo
  • Yue Wang
  • Jihong Zhu
  • Jie Cao
  • Zili Chen
  • Zhijun Li
  • Ximing Qian
چکیده

OBJECTIVES Aortic arch replacement is associated with increased mortality and morbidity especially in acute type-A aortic dissection. Although hypothermic circulatory arrest with selective antegrade cerebral perfusion has been widely used because of its excellent cerebral protection, its optimal perfusion characteristics are unknown. The present study investigates clinical results obtained after perfusion method modification and temperature management during cardiopulmonary bypass (CPB). METHODS Between July 2010 and August 2012, 16 consecutive adult patients (mean age 50.0 yr ± 14.1 yr, range 25 yr to 73 yr, 12 males, 4 females) who presented with acute Stanford type-A aortic dissection underwent aortic arch replacement (total arch, n = 11; hemiarch, n = 5) under mild hypothermia (31.1 °C ± 1.5 °C) with right axillary and femoral artery perfusion. RESULTS The mean CPB time was 201 min ± 53 min, and the mean myocardial ischemic time was 140 min ± 42 min. The mean selective cerebral perfusion time was 80 min ± 16 min, and the mean lower-body circulatory arrest time was 20 min ± 13 min. No patient death occurred within 30 post-operative days. The following details were observed: new post-operative permanent neurologic deficit in 1 patient (6.3%), temporary neurologic deficit in 2 patients (12.5%), acute renal dysfunction (creatinine level > 230 umol/L) in 3 patients (18.8%) and mechanical ventilation > 72 h in 5 patients (31.2%). CONCLUSIONS Aortic arch replacement for acute type-A aortic dissection under mild hypothermia with right axillary and femoral artery perfusion could be safely performed in the patient cohort.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Results of Ascending Aorta and Aortic Arch Replacement under Moderate Hypothermia with Right Brachial and Femoral Artery Perfusion

BACKGROUND Selective antegrade perfusion via axillary artery cannulation along with circulatory arrest under deep hypothermia has became a recent trend for performing surgery on the ascending aorta and aortic arch and when direct aortic cannulation is not feasible. The authors of this study tried using moderate hypothermia with right brachial and femoral artery perfusion to complement the pitfa...

متن کامل

Whole-body perfusion under moderate-degree hypothermia during aortic arch repair.

INTRODUCTION There continue to be some controversies concerning aortic arch reconstruction, especially the cerebral protection methods. We report our operative and postoperative outcomes for cases of aortic arch replacement using whole-body perfusion during aortic reconstruction under 28 degrees C moderate hypothermia. MATERIALS AND METHODS A total of 12 patients were operated on between Marc...

متن کامل

Evolving arch surgery using integrated antegrade selective cerebral perfusion: impact of axillary artery perfusion.

OBJECTIVE The study objective was to determine the impact of integrated antegrade selective cerebral perfusion with right axillary artery perfusion during arch surgery. METHODS All surgeries were performed through a median sternotomy. Direct cannulation of the right axillary artery in the axilla was used for cardiopulmonary bypass and antegrade selective cerebral perfusion under hypothermia. ...

متن کامل

Total arch replacement using antegrade selective cerebral perfusion with right axillary artery perfusion.

OBJECTIVE Right axillary artery (AxA) perfusion, which can prevent cerebral embolism caused by retrograde perfusion via the femoral artery (FA), was used for selective cerebral perfusion (SCP) as well as cardiopulmonary bypass (CPB) in aortic arch repair. We review the outcome of aortic arch surgery using SCP with right AxA perfusion to clarify its efficacy. METHOD Between 1998 and 2002, 120 ...

متن کامل

Double-arterial cannulation for aortic valve replacement with porcelain aorta.

We describe a new technique of aortic valve replacement (AVR) in patients with porcelain aorta. Three patients (mean age 75 years) were treated. The cardiopulmonary bypass (CPB) was established after side-graft right axillary artery and direct femoral artery cannulation. Venous drainage was obtained by atrio-caval cannulation. The procedures were performed in mild hypothermia (30 degrees C). Ce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014