Detection of enteric viruses in activated sludge by feasible concentration methods
نویسندگان
چکیده
Human enteric viruses are responsible to cause several diseases, including gastroenteritis and hepatitis, and can be present in high amounts in sewage sludge. This study compared virus recovery efficiency of two feasible concentration methods used for detecting human adenovirus (HAdV), rotavirus species A (RV-A), norovirus genogroup II (NoV GII) and hepatitis A virus (HAV) in sewage sludge from an activated sludge process. Twelve sewage sludge samples were collected bi-monthly from January to July, 2011. Ultracentrifugation was compared with a simplified protocol based on beef extract elution for recovering enteric viruses. Viruses were quantified by quantitative real-time PCR assays and virus recovery efficiency and limits of detection were determined. Methods showed mean recovery rates lower than 7.5%, presenting critical limits of detection (higher than 10(2) - 10(3) genome copies - GC L(-1) for all viruses analyzed). Nevertheless, HAdV were detected in 90% of the analyzed sewage sludge samples (range: 1.8 × 10(4) to 1.1 × 10(5) GC L(-1)), followed by RV-A and NoV (both in 50%) and HAV (8%). Results suggesting that activated sludge is contaminated with high viral loads and HAdV are widely disseminated in these samples. The low virus recovery rates achieved, especially for HAV, indicate that other feasible concentration methods could be developed to improve virus recovery efficiency in these environmental matrices.
منابع مشابه
Molecular Detection of Hepatitis A Virus in Urban Sewage in Isfahan, Iran
ABSTRACT Background and Objectives: Hepatitis A virus (HAV) enters sewage through the stool of infected patients and contaminates freshwater and seawater. The aim of present study was quantitative molecular detection of HAV in raw and treated urban sewage samples from Isfahan, center of Iran. &nbs...
متن کاملThe efficiency of concentration methods used to detect enteric viruses in anaerobically digested sludge
The presence of enteric viruses in biosolids can be underestimated due to the inefficient methods (mainly molecular methods) used to recover the viruses from these matrices. Therefore, the goal of this study was to evaluate the different methods used to recover adenoviruses (AdV), rotavirus species A (RVA), norovirus genogroup II (NoV GII) and the hepatitis A virus (HAV) from biosolid samples a...
متن کاملCoupled Anaerobic Baffled Reactor (ABR)/Activated Sludge Treatment of Synthetic Wastewater with High Concentration of Sulfate and COD
A synthetic wastewater with high concentration of sulfate and COD was treated in anaerobic baffled reactor (ABR) coupled with an activated sludge. The work was accomplished in two phases. In the first phase, the concentration of sulfate was kept constant at 500mg/l, but COD concentration was increased from (3000mg/l to 6000mg/l), consequently, COD and sulfate removal in ABR reached to 80% and 9...
متن کاملEffect of Concentration of Cations on Activated Sludge Properties and Membrane Fouling in Membrane Bioreactors for Wastewater Treatment
This paper presents the results of an investigation on the effects of concentration of cations on activated sludge properties and membrane fouling in submerge membrane bioreactors. The working volume of the experimental setup was two liters. The cellulose acetate membrane was immersed in the bioreactor. The flocculability, settling properties and fouling propensity of activated sludge was measu...
متن کاملNickel (II) Adsorption from Aqueous Solutions by Physico-Chemically Modified Sewage Sludge
This study assesses teh potential of activated carbon prepared from sewage sludge for nickel ions adsorption from aqueous solutions. Activated carbon physicochemical properties were determined. Batch adsorption experiments were performed as a function of pH solution, adsorbent dose, initial metal ions concentration, contact time and temperature. Teh experimental data were analyzed by teh La...
متن کامل