A randomised clinical trial to assess satisfaction with the levonorgestrel‐ releasing intrauterine system inserted at caesarean section compared to postpartum placement

نویسندگان

  • Kathleen Braniff
  • Edmund Gomez
  • Reinhold Muller
چکیده

BACKGROUND Insertion of levonorgestrel-releasing intrauterine system (LNG-IUS) at caesarean section (CS) provides contraception prior to resumption of ovulation or sexual activity. Patient satisfaction with insertion at CS has not previously been studied. AIMS The aim of this study was to compare patient satisfaction with LNG-IUS inserted at the time of lower uterine segment CS to six weeks postpartum. MATERIALS AND METHODS Open-label randomised controlled trial. Women booked for elective CS were randomised to LNG-IUS insertion either at the time of CS (study group) or at six weeks postpartum (control group). The primary outcome measure was patient satisfaction. Outcomes were measured at six weeks, three months and six months postpartum. RESULTS Forty-eight women were randomised into two treatment groups. Twenty-five women were randomised to have LNG-IUS inserted at the time of CS, 23 of whom had the planned intervention and two had the LNG-IUS inserted postpartum. Twenty-three women were randomised to the control group, four of whom withdrew prior to treatment. The 44 remaining women contributed to data analysis. Patient satisfaction was high and similar in both groups. At six months postpartum, 90.5% of the study group were very satisfied or somewhat satisfied compared with 88.2% of the control group. CONCLUSIONS Patient satisfaction is high with LNG-IUS insertion at CS and not different to that with delayed insertion. LNG-IUS insertion may be an option for women who find postpartum contraception difficult to access.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Postplacental or delayed insertion of the levonorgestrel intrauterine device after vaginal delivery: a randomized controlled trial.

OBJECTIVE To estimate whether 6-month use of the levonorgestrel-releasing intrauterine device (IUD) would be higher when insertion occurred within 10 minutes of placental delivery compared with 6-8 weeks postpartum. METHODS We enrolled pregnant women planning vaginal deliveries and desiring a postpartum levonorgestrel-releasing IUD. Patients were randomly assigned when admitted in labor to po...

متن کامل

Management of initial bleeding or spotting after levonorgestrel-releasing intrauterine system placement: a randomized controlled trial.

OBJECTIVE To assess the efficacy of tranexamic acid or mefenamic acid in the management of the initial "nuisance" bleeding or spotting in the period immediately after placement of the levonorgestrel-releasing intrauterine system. METHODS Women were randomized after levonorgestrel-releasing intrauterine system placement to oral tranexamic acid (500 mg), mefenamic acid (500 mg), or placebo thre...

متن کامل

A randomized clinical trial to compare levonorgestrel-releasing intrauterine system (Mirena) vs trans-cervical endometrial resection for treatment of menorrhagia

OBJECTIVE To compare the acceptability, efficacy, adverse effects, and user satisfaction of the levonorgestrel intrauterine system (LNG-IUS) and trans-cervical resection of the endometrium (TCRE) for the treatment of menorrhagia. METHOD 104 women with menorrhagia were divided into 2 groups: 52 women had the LNG-IUS inserted and 52 underwent TCRE. Menstrual pattern, pictorial blood loss assess...

متن کامل

Open randomised study of use of levonorgestrel releasing intrauterine system as alternative to hysterectomy.

OBJECTIVES To assess whether the levonorgestrel intrauterine system could provide a conservative alternative to hysterectomy in the treatment of excessive uterine bleeding. DESIGN Open randomised multicentre study with two parallel groups: a levonorgestrel intrauterine system group and a control group. SETTING Gynaecology departments of three hospitals in Finland. SUBJECTS Fifty six women...

متن کامل

The Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report

Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 55  شماره 

صفحات  -

تاریخ انتشار 2015