Bipolar electrogram shannon entropy at sites of rotational activation: implications for ablation of atrial fibrillation.

نویسندگان

  • Anand N Ganesan
  • Pawel Kuklik
  • Dennis H Lau
  • Anthony G Brooks
  • Mathias Baumert
  • Wei Wen Lim
  • Shivshankar Thanigaimani
  • Sachin Nayyar
  • Rajiv Mahajan
  • Jonathan M Kalman
  • Kurt C Roberts-Thomson
  • Prashanthan Sanders
چکیده

BACKGROUND The pivot is critical to rotors postulated to maintain atrial fibrillation (AF). We reasoned that wavefronts circling the pivot should broaden the amplitude distribution of bipolar electrograms because of directional information encoded in these signals. We aimed to determine whether Shannon entropy (ShEn), a measure of signal amplitude distribution, could differentiate the pivot from surrounding peripheral regions and thereby assist clinical rotor mapping. METHODS AND RESULTS Bipolar electrogram recordings were studied in 4 systems: (1) computer simulations of rotors in a 2-dimensional atrial sheet; (2) isolated rat atria recorded with a multi-electrode array (n=12); (3) epicardial plaque recordings of induced AF in hypertensive sheep (n=11); and (4) persistent AF patients (n=10). In the model systems, rotation episodes were identified, and ShEn calculated as an index of amplitude distribution. In humans, ShEn distribution was analyzed at AF termination sites and with respect to complex fractionated electrogram mean. We analyzed rotation episodes in simulations (4 cycles) and animals (rats: 14 rotors, duration 80±81 cycles; sheep: 13 rotors, 4.2±1.5 cycles). The maximum ShEn bipole was consistently colocated with the pivot zone. ShEn was negatively associated with distance from the pivot zone in simulated spiral waves, rats, and sheep. ShEn was modestly inversely associated with complex fractionated electrogram; however, there was no relationship at the sites of highest ShEn. CONCLUSIONS ShEn is a mechanistically based tool that may assist AF rotor mapping.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the characteristics of rotational activation at high-dominant frequency and complex fractionated atrial electrogram sites during atrial fibrillation

BACKGROUND High-dominant frequency (DF) and continuous complex fractionated atrial electrogram (CFAE) sites as surrogates for localized sources maintaining atrial fibrillation (AF) are potential AF ablation targets. This study aimed to evaluate the characteristics of a rotational activation at high-DF and continuous CFAE sites in AF patients. METHODS Thirty-two consecutive AF patients (5 paro...

متن کامل

Novel approaches for quantitative electrogram analysis for intraprocedural guidance for catheter ablation: A case of a patient with persistent atrial fibrillation

Purpose Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia that causes stroke affecting more than 2.3 million people in the US and is increasing in prevalence due to ageing population causing a new global epidemic. Catheter ablation with pulmonary vein isolation (PVI) to terminate AF is successful for paroxysmal AF but suffers limitations with persistent AF patients as cur...

متن کامل

Dynamic Approximate Entropy Electroanatomic Maps Detect Rotors in a Simulated Atrial Fibrillation Model

There is evidence that rotors could be drivers that maintain atrial fibrillation. Complex fractionated atrial electrograms have been located in rotor tip areas. However, the concept of electrogram fractionation, defined using time intervals, is still controversial as a tool for locating target sites for ablation. We hypothesize that the fractionation phenomenon is better described using non-lin...

متن کامل

Origin and Characteristics of High Shannon Entropy at the Pivot of Locally Stable Rotors: Insights from Computational Simulation

BACKGROUND Rotors are postulated to maintain cardiac fibrillation. Despite the importance of bipolar electrograms in clinical electrophysiology, few data exist on the properties of bipolar electrograms at rotor sites. The pivot of a spiral wave is characterized by relative uncertainty of wavefront propagation direction compared to the periphery. The bipolar electrograms used in electrophysiolog...

متن کامل

Quantitative analysis of localized sources identified by focal impulse and rotor modulation mapping in atrial fibrillation.

BACKGROUND New approaches to ablation of atrial fibrillation (AF) include focal impulse and rotor modulation (FIRM) mapping, and initial results reported with this technique have been favorable. We sought to independently evaluate the approach by analyzing quantitative characteristics of atrial electrograms used to identify rotors and describe acute procedural outcomes of FIRM-guided ablation. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 6 1  شماره 

صفحات  -

تاریخ انتشار 2013