Repeatability and concordance of the Pentacam system. Comparative study of corneal parameters measured with Pentacam and Atlas Repetibilidad y concordancia de un sistema Pentacam. Comparación de parámetros corneales medidos con Pentacam y con Atlas
نویسندگان
چکیده
REFERENCES AND LINKS [1] W. N. Charman, “The retinal image in the human eye”, in Progress in Retinal Research, Pergamon, Oxford (1983). [2] A. A. Atchison, G. Smith, Optics of the Human Eye, Butterworth-Heinnemann, Oxford (2000). [3] P. Artal, A. Guirao, “Contribution of corneal and lens to the aberrations of the human eye”, Opt. Lett. 23, 1713-1715 (1998). [4] A. Guirao, P. Artal, “Corneal wave-aberrations from videokeratography: accuracy and limitations of the procedure”, J. Opt. Soc. Am. A 17, 955-965 (2000). [5] F. H. M. Jongsma, J. de Brabander, F. Hendrikse, “Review and classification of corneal topographers”, Laser Med. Sci. 14, 2-19 (1999). [6] A. Konstantopoulos, P. Hossain, D. F. Anderson, “Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis?”, Brit. J Ophthalmol. 91, 551-557 (2007). [7] C. O'Donnell, C. Maldonado-Codina, “Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the OCULUS pentacam”, Cornea 24, 920-924 (2005). ABSTRACT:
منابع مشابه
Comparison of Central Corneal Thickness Measured through Pentacam, OCTCasia2, and Orbscan IIz in Normal Individuals
Purpose: To compare the central corneal thickness measured through Pentacam, OCTCasia2, and Orbscan IIz in normal individuals. Methods: In this cross sectional comparative study, the researcher investigated the eyes of 70 normal candidates (140 eyes) with the mean age of 31.42 ± 7.70, referring to Dr. Sedaghat eye clinic for refractive surgery. For each person, Central Corneal Thickness (CCT) w...
متن کاملEfficacy of Orbscan II and Pentacam topographers by a repeatability analysis when assessing elevation maps in candidates to refractive surgery.
INTRODUCTION Anterior and posterior corneal elevations are measurements used to detect keratoconus suspects. PURPOSE To determine the efficacy of Orbscan II and Pentacam when assessing their elevation maps. MATERIALS AND METHODS The efficacy of the Orbscan II and Pentacam measuring the anterior and posterior corneal elevations were evaluated in a sample of 68 eyes. The concordance between t...
متن کاملCentral corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry.
PURPOSE To assess the intraoperator repeatability and interoperator reproducibility of central corneal thickness measurements by the Pentacam Scheimpflug imaging system (Oculus) and the optical low-coherence reflectometer (OLCR) pachymeter (Haag-Streit) and to compare them with those of ultrasound (US) pachymetry. SETTING Assaf Harofe Medical Center Ophthalmology Outpatient Clinic, Zerifin, I...
متن کاملAnterior Segment Parameters Using Pentacam and Prediction of Corneal Endothelial Cell Loss after Cataract Surgery
PURPOSE We evaluated various preoperative anterior segment parameters measured with a Pentacam rotating Scheimpflug camera and compared them with those of conventional methods. We also evaluated the effect of different parameters on corneal endothelial cells after cataract surgery. METHODS Pentacam examination was performed in 88 eyes from 88 patients to evaluate central anterior chamber dept...
متن کاملRepeatability and Agreement of Central Corneal Thickness and Keratometry Measurements between Four Different Devices
Background. To estimate repeatability and comparability of central corneal thickness (CCT) and keratometry measurements obtained by four different devices in healthy eyes. Methods. Fifty-five healthy eyes from 55 volunteers were enrolled in this study. CCT (IOLMaster 700, Pentacam HR, and Cirrus HD-OCT) and keratometry readings (IOLMaster 700, Pentacam HR, and iDesign) were measured. For statis...