Application of FSW to Join Aluminium Foil Winding Coils for Electrical Transformers

نویسندگان

  • Pedro Vilaça
  • Joel Mendes
  • Filipe Nascimento
  • Luísa Quintino
چکیده

The technically pure copper is being replaced by aluminium as conductive material in electrical transformers for power systems. This evolution brings new manufacturing challenges. One major difficulty is the limited weld ability and non-acceptable residual deformations of the aluminium, when welded by fusion arc welding processes. The Friction Stir Welding (FSW) was selected for evaluation considering the requisites of the application on mechanical strength, distortion and electrical conductivity. The current work evaluates the feasibility of application of FSW to join successive residual aluminium foil winding coils, into new longer foil winding coils. The residual foil winding coils are made of AA1070 with 1.6 mm thick and 1100 mm wide. The residual foil winding coils are butt jointed by FSW and rewind in one new longer foil winding until the total length of the new bobbin already enables its application in the production of new components for high voltage electrical transformers. This way, the FSW may be used as key technique to add-value and promote a more sustainable industrial production system. Each of the residual foil winding coils had an average weight of about 250 kg, which required the development of dedicated supporting, positioning and clamping systems. The technological conditions to be implemented in real scale are initially developed in 300 mm length welds. The analysis of the results addresses the mechanical resistance, hardness distribution and metallurgical properties of the resulting joint zones. It was demonstrated the technological feasibility of joining by FSW, and rewind, residual winding foils, to produce new coils complying with the requirements for distortion, mechanical strength and electrical resistance properties. Application of FSW to Join Aluminium Foil Winding Coils for Electrical Transformers Publication History: Received: January 25, 2016 Accepted: June 13, 2016 Published: June 15, 2016

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermal Analysis of Foil Wound Concentrated Coils for Use in Axial Flux Permanent Magnet Alternators

Axial flux permanent magnet (AFPM) generators for small-scale wind turbine applications have proven to be a useful design due to their reliability and ease of construction. Their stators have been realized using concentrate coils of enameled copper wires embedded in an epoxy-resin composite mixture. A static setting, opposed to a dynamic machine environment, is utilized to study the steady stat...

متن کامل

Influence of the Parameters of Disk Winding on the Impulse Voltage Distribution in Power Transformers

Overvoltage distribution along the transformer winding must be uniform to certify the safety of the operation of the power transformer. Influence of the parameters variation on the impulse voltage distribution (IVD) in disk winding transformer is going to be analyzed which hasn’t been analyzed on this type of winding in the previous papers. In this research, a transformer with disk winding and ...

متن کامل

Characterization of Power Transformer Electromagnetic Forces Affected by Winding Faults

Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...

متن کامل

Selection of copper against aluminium windings for distribution transformers

Copper and aluminium are the two conductors most commonly used in transformer windings. This study presents a comprehensive comparison of distribution transformers built either with copper or with aluminium windings. The comparison is based on winding material conductivity, density, cost, connectivity, oxidation, machinability and behaviour under short-circuit. Additionally, a parametric analys...

متن کامل

Modeling the Frequency Response Movements in Power Transformers for Predicting Purposes

Power transformers are key components in electrical power supplies and their failure could cause severe consequences on continuity of service and also generates substantial costs. Identifying problems at an early stage, before catastrophic failure occurs, is a great benefit for reliable operation of power transformers. Frequency Response Analysis (FRA) is a new, well-known and powerful diagnost...