Novel flat and wide meniscal repair material improves the ultimate load of knot breakage in a porcine trans-capsular meniscal repair model

نویسندگان

  • Hiroyuki Yokoi
  • Tatsuo Mae
  • Ryo Iuchi
  • Yasuhiro Take
  • Yuta Tachibana
  • Kazunori Shimomura
  • Tomoki Ohori
  • Konsei Shino
  • Hideki Yoshikawa
  • Ken Nakata
چکیده

BACKGROUND In the meniscal repair procedures, a high ultimate load capacity and low cyclic creep at the repair site are favorable and lead to good biological incorporation of the tear site after surgery. Previous biomechanical tensile tests of the meniscal sutures have identified the suture knot as the weakest point. We hypothesized that the strength of a suture knot depends on the suture shape, and therefore, we compared three differently shaped suture materials composed of the same material and quantity per length. The purpose of this study was to determine whether a novel flat and wide repair material (FWRM), which consists of braided multi-threads that are cross-sectionally flat and wide, improves the ultimate load of knot breakage in a biomechanical experiment using a porcine trans-capsular meniscal repair model. METHODS Eighteen fresh-frozen porcine knees (n = 6 in each group) were used. A longitudinal tear in the middle segment of the medial meniscus was created and repaired with a trans-capsular inside-out method using the following suture materials: No. 2-0 braided polyester conventional suture, hollow suture, and FWRM. After the separation of the inner segment of the meniscus with leaving, the suture stability of the repaired menisci was biomechanically analyzed with a video camera system for widening after a cyclic load between 5 and 20 N was applied 300 times. Ultimate failure load and stiffness at 5 mm/ min were also analyzed. RESULTS We found no significant difference in suture widening after cyclic load tests [conventional suture, mean 0.51 mm (S.D. 0.39 mm); hollow suture, mean 0.23 mm (S.D. 0.11 mm); and FWRM, mean 0.54 mm (S.D. 0.08 mm)]. The failure mode in all specimens was knot breakage. Compared with those of the other groups, the ultimate failure load of FWRM was statistically significantly higher in the load-to-failure tests (conventional suture, mean 58.8 N [S.D. 8.25 N]; hollow suture, mean 79.4 N [S.D. 10.2 N]; and FWRM, mean 97.4 N [S.D. 3.65 N]; p < 0.05). CONCLUSION FWRM improves the ultimate load of knot breakage without altering stability. This material may contribute to safe and stable meniscus repair.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Results of Meniscal Repair Using Submeniscal Horizontal Sutures

Background:  Parts of the implants placed over the meniscus during meniscal repair can wear down the cartilage in the contact zones and cause chronic synovitis. Placing horizontal sutures under the meniscus may overcome this potential hazard. The purpose of this prospective study was to evaluate the midterm results of arthroscopic meniscal repair using submeniscally placed out-in horizontal sut...

متن کامل

Arthroscopic Meniscal Repair: “Modified Outside-In Technique”

Background:  Despite the introduction of different techniques for meniscal repair, no single procedure is superior in all situations. The new method for meniscal repair named “ modified outside-in technique ” aims to achieve higher primary fixation strength by an alternative suture technique as well as avoid disadvantages of outside-in, inside-out, and all-inside suture procedures. Additionally...

متن کامل

Load to failure testing of new meniscal repair devices.

PURPOSE New all-inside meniscal repair devices include those combining sutures with anchors and that allow for an "adjustable" repair. This study's purpose was to compare the failure strength of new meniscal repair devices with suture repairs. TYPE OF STUDY Experimental laboratory biomechanical study. METHODS A single repair was placed in a vertical longitudinal peripheral tear made in fres...

متن کامل

Tensile and shear loading stability of all-inside meniscal repairs: an in vitro biomechanical evaluation.

BACKGROUND Most biomechanical studies for evaluation of the structural properties of meniscal repairs have been performed in tensile loading scenarios perpendicular to the circumferential meniscal fibers. However, meniscal repair constructs are also exposed to shear forces parallel to the circumferential meniscal fibers during healing, particularly in the midportion of the meniscus. HYPOTHESI...

متن کامل

ARTHROSCOPIC MODIFIED ALL-INSIDE LATERAL MENISCAL TEAR REPAIR USING TWO POSTERIOR PORTAL TECHNICAL NOTE

This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -