Immediate hemodynamic response of patients with atrioventricular block and cardiac failure to transvenous pacing.
نویسندگان
چکیده
Immediate hemodynamic improvement in patients with complete heart block occurs when the ventricular rate is increased by electrical pacing. During pacing, there is reduction in the pulmonary artery wedge, right atrial, and left and right ventricular filling pressures. The mean rate of ejection, stroke volume, and stroke work decreased following pacing, whereas the ejection time per minute increased, and dye curves assumed a more normal configuration. Very little change was noted in the resting cardiac output. The paced heart is able to obtain greater increases in cardiac output, stroke volume, and mean rate of ejection during exercise than when unpaced. In addition, pacing tends to return elevated exercising filling pressures in the right and left ventricles toward normal.
منابع مشابه
Cardiac resynchronization therapy via transvenous approach in a 2-year-old boy with a complete atrioventricular block after a tetralogy of Fallot repair
Cardiac resychronization therapy (CRT) was performed via transvenous approach in a 2-year-old boy with a tetralogy of Fallot and postoperative severe heart failure, and complete atrioventricular block treated with a dual-chamber pacemaker. Epicardial leads were unavailable because of mediastinitis and the presence of severe bilateral pleural effusions requiring continuous drainage. There were n...
متن کاملLeft ventricular endocardial or triventricular pacing to optimize cardiac resynchronization therapy in a chronic canine model of ischemic heart failure.
Cardiac resynchronization therapy (CRT) is a proven treatment for heart failure but ~30% of patients appear to not benefit from the therapy. Left ventricular (LV) endocardial and multisite epicardial [triventricular (TriV)] pacing have been proposed as alternatives to traditional LV transvenous epicardial pacing, but no study has directly compared the hemodynamic effects of these approaches. Le...
متن کاملTrans-Fontan baffle placement of an endocardial systemic ventricular pacing lead
Introduction Patients with single-ventricle physiology palliated to a Fontan can be at risk for high-grade atrioventricular block, necessitating permanent pacemaker placement. Historically, epicardial leads have been used for these patients given the concern for clot formation within the Fontan pathway or systemic ventricle. However, epicardial pacing systems are fraught with issues, including ...
متن کاملTransvenous dual‐chamber pacemaker after paediatric heart transplantation using left ventricle pacing through the coronary sinus
A 12-year-old child with end-stage heart failure due to restrictive cardiomyopathy was submitted to orthotopic heart transplantation. Primary graft dysfunction required venous arterial extra-corporeal membrane oxygenation. Heart function normalized, but complete atrioventricular block remained after 3 weeks. A dual-chamber pacing with transvenous left ventricle pacing through the coronary sinus...
متن کاملfulguration of atrioventricular conduction
Twenty nine patients who had had refractory supraventricular tachycardia were studied 4-36 (mean 16) months after transvenous fulguration of the atrioventricular junction. Twenty two had complete atrioventricular block, five partial atrioventricular block, and two had atrioventricular conduction via an accessory atrioventricular pathway. Though all patients were free of palpitation after the pr...