Ii7 situ absolute calibration of a channel electron multipkr for detection of positive ions
نویسندگان
چکیده
A technique has been developed to determine the absolute single particle counting efficiency of a channel electron multiplier (CEM) for positively charged ions at keV energies. The calibration technique is applicable to positive ion detectors in general. Ion beam currents of C?+ were created by charge transfer of C? on H, in the thin target regime. By adjusting the Hz pressure in the beam scattering chamber from lo-” to 10Y6 Torr, C2’ currents could be created either low enough to be detected by the CEM in the particle counting mode or high enough to be measured as a current using the CEM as a Faraday cup. The CEM counting efficiency was determined by comparing the C2’ count rate to the C?’ current, scaling by the change in H2 pressure, and also scaling by the incident C?+ current for each C? measurement. This method, which effectively uses the charge transfer cross section as a “transfer standard,” allows the CEM counting efficiency to be determined in situ and to be monitored accurately over extended periods of time. The calibration requires that only the relative, not the absolute, pressure change be known. The technique does not require the value of the charge transfer cross section to be known. The accuracy of the calibration technique for the present results was 10% at a confidence level considered to be equivalent to a statistical 90% confidence level. For the present work, the peak counting efficiency of a Galileo 4039 CEM for 32.5 keV C? ions was determined to be 96%. 0 I995 American Institute ofPhysics.
منابع مشابه
Investigation of relationship with electron configuration of chemical hardness, absolute electronegativity and electrophilicity
Chemical hardness (), absolute electronegativity (), and electrophilicity () have importantapplications in inorganic chemistry. These concepts are defined quantitatively as � � �� � ����,� � �� � ����, � � ������Where I is the ionization energy and A is the electron affinity. In thisstudy, graphical method was used to see the relation of electron configuration with chemicalhardness, absolute el...
متن کاملRadiation Pressure effects on ion Acceleration on the GEMINI laser
We report on the absolute calibration of amicro channel plate (MCP) detector, installed asdetector in a Thomson parabola spectrometer. Thecalibration delivers the relation between a registeredcount numbers in the CCD camera (on which the MCPphosphor screen is imaged) as a result of the impact ofan ion beam onto the MCP. The particle response ofthe whole detection...
متن کاملSimulation study of the transport properties of ions through ion channels serving as primary components of a nanobiosensor
Ion channels are naturally occurring pores through the proteins that regulate the passage of ions and thus maintain the concentration of ions inside and outside the cell. The ion channels control many physiological functions and they can show selectivity for a specific ion. Ion channels are mostly observed in nerve cells and muscle cells. The influx of ions into cells can be regulated by a gate...
متن کاملSimulation study of the transport properties of ions through ion channels serving as primary components of a nanobiosensor
Ion channels are naturally occurring pores through the proteins that regulate the passage of ions and thus maintain the concentration of ions inside and outside the cell. The ion channels control many physiological functions and they can show selectivity for a specific ion. Ion channels are mostly observed in nerve cells and muscle cells. The influx of ions into cells can be regulated by a gate...
متن کاملSpectrophotometric determination of total phenol in fish muscle after in- situ derivatization and reverse phase dispersive liquid- liquid microextraction
Abstract Reverse phase dispersive liquid- liquid microextraction (RP- DLLME) coupled with spectrophotometry is introduced for the detection of total phenol in the muscle tissue of fishes, such as Sphyraena genie, Otolithes ruber, Rastrelliger kangurta, Lutjanus johnii and Barbus Subquin Cunciatus. Phenols in fish tissues were extracted by ultrasonic bath and derivatization with 4- aminoant...
متن کامل