The discrepancy between human peripheral nerve chronaxie times as measured using magnetic and electric field stimuli: the relevance to MRI gradient coil safety
نویسندگان
چکیده
Peripheral nerve stimulation (PNS) resulting from electric fields induced from the rapidly changing magnetic fields of gradient coils is a concern in MRI. Nerves exposed to either electric fields or changing magnetic fields would be expected to display consistent threshold characteristics, motivating the direct application of electric field exposure criteria from the literature to guide the development of gradient magnetic field exposure criteria for MRI. The consistency of electric and magnetic field exposures was tested by comparing chronaxie times for electric and magnetic PNS curves for 22 healthy human subjects. Electric and magnetic stimulation thresholds were measured for exposure of the forearm using both surface electrodes and a figure-eight magnetic coil, respectively. The average chronaxie times for the electric and magnetic field conditions were 109 ± 11 μs and 651 ± 53 μs (±SE), respectively. We do not propose that these results call into question the basic mechanism, namely that rapidly switched gradient magnetic fields induce electric fields in human tissues, resulting in PNS. However, this result does motivate us to suggest that special care must be taken when using electric field exposure data from the literature to set gradient coil PNS safety standards in MRI. 3 Author to whom any correspondence should be addressed. 0031-9155/09/195965+15$30.00 © 2009 Institute of Physics and Engineering in Medicine Printed in the UK 5965 5966 B J Recoskie et al
منابع مشابه
Comments on 'the discrepancy between human peripheral nerve chronaxie times as measured using magnetic and electric field stimuli: the relevance to MRI gradient coil safety'.
A recent electrostimulation study with human subjects (Recoskie et al 2009 Phys. Med. Biol. 54 5965-79) reported a large difference between chronaxie times when stimuli were delivered to the same body locus (the wrist) either through contact electrodes (electric stimulation) or through a pulsed magnetic field (magnetic stimulation). This paper reviews the procedures and analytic methods used in...
متن کاملPeripheral nerve stimulation properties of head and body gradient coils of various sizes.
Peripheral nerve stimulation (PNS) caused by time-varying magnetic fields has been studied both theoretically and experimentally. A human volunteer study performed on three different body-size gradient coils and one head-size gradient coil is presented in this work. The experimental results were used to generate average PNS threshold parameters for the tested gradient systems. It was found that...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملConsideration of magnetically-induced and conservative electric fields within a loaded gradient coil.
We present a method to calculate the electric (E)-fields within and surrounding a human body in a gradient coil, including E-fields induced by the changing magnetic fields and "conservative" E-fields originating with the scalar electrical potential in the coil windings. In agreement with previous numerical calculations, it is shown that magnetically-induced E-fields within the human body show n...
متن کاملAssessment of Reproducibility of Geometric Distortion in MRI using Phantom Measurements
Introduction: Image distortion is one of the major problems of magnetic resonance imaging (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is widely known that the most obvious effect of the inhomogenity of the magnetic fields and the nonlinearity of the gradient is the Geometric Distortion of MR tomograms. In this study, the...
متن کامل