Interactive initialization of 2D/3D rigid registration.

نویسندگان

  • Ren Hui Gong
  • Özgür Güler
  • Mustafa Kürklüoglu
  • John Lovejoy
  • Ziv Yaniv
چکیده

PURPOSE Registration is one of the key technical components in an image-guided navigation system. A large number of 2D/3D registration algorithms have been previously proposed, but have not been able to transition into clinical practice. The authors identify the primary reason for the lack of adoption with the prerequisite for a sufficiently accurate initial transformation, mean target registration error of about 10 mm or less. In this paper, the authors present two interactive initialization approaches that provide the desired accuracy for x-ray/MR and x-ray/CT registration in the operating room setting. METHODS The authors have developed two interactive registration methods based on visual alignment of a preoperative image, MR, or CT to intraoperative x-rays. In the first approach, the operator uses a gesture based interface to align a volume rendering of the preoperative image to multiple x-rays. The second approach uses a tracked tool available as part of a navigation system. Preoperatively, a virtual replica of the tool is positioned next to the anatomical structures visible in the volumetric data. Intraoperatively, the physical tool is positioned in a similar manner and subsequently used to align a volume rendering to the x-ray images using an augmented reality (AR) approach. Both methods were assessed using three publicly available reference data sets for 2D/3D registration evaluation. RESULTS In the authors' experiments, the authors show that for x-ray/MR registration, the gesture based method resulted in a mean target registration error (mTRE) of 9.3 ± 5.0 mm with an average interaction time of 146.3 ± 73.0 s, and the AR-based method had mTREs of 7.2 ± 3.2 mm with interaction times of 44 ± 32 s. For x-ray/CT registration, the gesture based method resulted in a mTRE of 7.4 ± 5.0 mm with an average interaction time of 132.1 ± 66.4 s, and the AR-based method had mTREs of 8.3 ± 5.0 mm with interaction times of 58 ± 52 s. CONCLUSIONS Based on the authors' evaluation, the authors conclude that the registration approaches are sufficiently accurate for initializing 2D/3D registration in the OR setting, both when a tracking system is not in use (gesture based approach), and when a tracking system is already in use (AR based approach).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated 3D Rigid Registration of Open 2D Manifolds

We present a robust method for 3D rigid registration of 2D open manifolds based on distance maps using an initialization step, a Gibbs sampler for optimization supplemented by an Iterated Conditional Modes (ICM) optimizer. The algorithm is fully automatic based on very simple information of the initial orientation of the given objects.

متن کامل

Interactive initialization for 2D/3D intra-operative registration using the Microsoft Kinect

All 2D/3D anatomy based rigid registration algorithms are iterative, requiring an initial estimate of the 3D data pose. Current initialization methods have limited applicability in the operating room setting, due to the constraints imposed by this environment or due to insufficient accuracy. In this work we use the Microsoft Kinect device to allow the surgeon to interactively initialize the reg...

متن کامل

RegistrationShop: An Interactive 3D Medical Volume Registration System

In medical imaging, registration is used to combine images containing information from different modalities or to track treatment effects over time in individual patients. Most registration software packages do not provide an easy-to-use interface that facilitates the use of registration. 2D visualization techniques are often used for visualizing 3D datasets. RegistrationShop was developed to i...

متن کامل

Automatic Extraction of Femur Contours from Calibrated X-Ray Images using Statistical Information

Automatic identification and extraction of bone contours from x-ray images is an essential first step task for further medical image analysis. In this paper we propose a 3D statistical model based framework for the proximal femur contour extraction from calibrated x-ray images. The automatic initialization to align the 3D model with the x-ray images is solved by an Estimation of Bayesian Networ...

متن کامل

Fast non-rigid registration and model-based segmentation of 3D images using mutual information

In this paper, we present a method to register medical images non-rigidly and to determine critical structures using a model-based segmentation. We present our method in the case of 2D and 3D magnetic resonance images (MRI) of the brain. In our approach, we rst use an existing algorithm for rigid matching of medical images by Mutual Information maximization for the initialization of our registr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 40 12  شماره 

صفحات  -

تاریخ انتشار 2013