Comparison of two automatic methods for the assessment of brachial artery flow-mediated dilation.

نویسندگان

  • Francesco Faita
  • Stefano Masi
  • Stavros Loukogeorgakis
  • Vincenzo Gemignani
  • Mike Okorie
  • Elisabetta Bianchini
  • Marietta Charakida
  • Marcello Demi
  • Lorenzo Ghiadoni
  • John Eric Deanfield
چکیده

OBJECTIVES Brachial artery flow-mediated dilation (FMD) is associated with risk factors providing information on cardiovascular prognosis. Despite the large effort to standardize the methodology, the FMD examination is still characterized by problems of reproducibility and reliability that can be partially overcome with the use of automatic systems. We developed real-time software for the assessment of brachial FMD (FMD Studio, Institute of Clinical Physiology, Pisa, Italy) from ultrasound images. The aim of this study is to compare our system with another automatic method (Brachial Analyzer, MIA LLC, IA, USA) which is currently considered as a reference method in FMD assessment. METHODS The agreement between systems was assessed as follows. Protocol 1: Mean baseline (Basal), maximal (Max) brachial artery diameter after forearm ischemia and FMD, calculated as maximal percentage diameter increase, have been evaluated in 60 recorded FMD sequences. Protocol 2: Values of diameter and FMD have been evaluated in 618 frames extracted from 12 sequences. RESULTS All biases are negligible and standard deviations of the differences are satisfactory (protocol 1: -0.27 ± 0.59%; protocol 2: -0.26 ± 0.61%) for FMD measurements. Analysis times were reduced (-33%) when FMD Studio is used. Rejected examinations due to the poor quality were 2% with the FMD Studio and 5% with the Brachial Analyzer. CONCLUSIONS In conclusion, the compared systems show a optimal grade of agreement and they can be used interchangeably. Thus, the use of a system characterized by real-time functionalities could represent a referral method for assessing endothelial function in clinical trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the effect of continuous and interval aerobic training on brachial artery diameter and endothelial function in a patient with coronary artery bypass grafting surgery

Introduction: Cardiovascular diseases, especially coronary artery disease, is one of the leading causes of death worldwide. Accordingly, the present study aimed to compare the effects of continuous and interval aerobic training on brachial artery diameter and endothelial function in coronary artery bypass graft patients. Materials and Methods: The present study encompassed 30 male patients meet...

متن کامل

Risk stratification for postoperative cardiovascular events via noninvasive assessment of endothelial function: a prospective study.

BACKGROUND Brachial artery endothelial function is impaired in individuals with atherosclerosis and coronary risk factors and improves with risk reduction therapy. However, the predictive value of brachial artery endothelial dysfunction for future cardiovascular events is unknown. METHODS AND RESULTS We preoperatively examined brachial artery vasodilation using ultrasound in 187 patients unde...

متن کامل

Flow mediated dilation of the brachial artery: an investigation of methods requiring further standardization

BACKGROUND In order to establish a consistent method for brachial artery reactivity assessment, we analyzed commonly used approaches to the test and their effects on the magnitude and time-course of flow mediated dilation (FMD), and on test variability and repeatability. As a popular and noninvasive assessment of endothelial function, several different approaches have been employed to measure b...

متن کامل

Relationship Between Brachial Artery Flow-Mediated Dilation, Carotid Artery Intima-Media Thickness and Coronary Flow Reserve in Patients With Coronary Artery Disease

BACKGROUND The aim of this study was to assess the relationship between brachial artery flow mediated dilation (FMD), carotid artery intima-media thickness (IMT) and coronary flow reserve (CFR) in patients with coronary artery disease (CAD). METHODS Fifty patients with coronary artery disease, except left anterior descending artery (LAD), who showed no cardiac symptoms and 45 control subjects...

متن کامل

The effect of reactive artery hyperaemia on the radial strain of the brachial artery: Definition of optimum cuff position

Instruction: Measurement of brachial artery diameter variation by ultrasound methods has commonly been used to test the endothelial function. It is known that the artery diameter is increased by flow stimulation. Therefore in the present study, the effect of external obstruction, as flow stimulation, on the radial strain of the brachial artery was assessed. Also the biomechanical behavior of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of hypertension

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 2011