Performance of bedside transpulmonary thermodilution monitoring for goal-directed hemodynamic management after subarachnoid hemorrhage.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Early goal-directed hemodynamic therapy is of particular importance for adequate cerebral circulation of patients with vasospasm after subarachnoid hemorrhage but is often precluded by the invasiveness of established cardiac output determination using a pulmonary artery catheter. This study was undertaken to validate the usefulness of less invasive goal-directed hemodynamic monitoring by transpulmonary thermodilution technique in patients after subarachnoid hemorrhage. METHODS One hundred sixteen patients with subarachnoid hemorrhage who underwent surgical clipping within 24 hours of ictus were investigated. Validation of transpulmonary thermodilution-derived intermittent/continuous cardiac output and cardiac preload (global end diastolic volume) were compared with pulmonary artery catheter-derived reference cardiac output and pulmonary capillary wedge pressure or central venous pressure in 16 patients diagnosed with vasospasm. In a subsequent trial of 100 consecutive cases, clinical results between the new and standard management paradigms were compared. RESULTS Transpulmonary thermodilution-derived intermittent cardiac output and transpulmonary thermodilution-derived continuous cardiac output showed close agreement to catheter-derived reference cardiac output with high correlation (r=0.85 and 0.77) and low percentage error (13.5% and 18.0%). Fluid responsiveness to defined volume loading was predicted better with global end diastolic volume than with pulmonary capillary wedge pressure and central venous pressure for larger receiver operating characteristic curve area. Patients receiving early goal-directed management by transpulmonary thermodilution experienced reduced frequencies of vasospasm and cardiopulmonary complications compared with those managed with standard therapy (P<0.05), whereas their functional outcomes at 3 months were not different (P=0.06). CONCLUSIONS Goal-directed hemodynamic management guided by transpulmonary thermodilution appears to have a therapeutic advantage for optimizing the prognosis of patients with subarachnoid hemorrhage with vasospasm over conventional methods.
منابع مشابه
Goal-directed fluid management by bedside transpulmonary hemodynamic monitoring after subarachnoid hemorrhage.
BACKGROUND AND PURPOSE Optimal monitoring of cardiac output and intravascular volume is of paramount importance for good fluid management of patients with subarachnoid hemorrhage (SAH). The aim of this study was to demonstrate the feasibility of advanced hemodynamic monitoring with transpulmonary thermodilution and to provide descriptive data early after SAH. METHODS Forty-six patients with S...
متن کاملPerformance of Third-generation FloTrac/Vigileo system during hyperdynamic therapy for delayed cerebral ischemia after subarachnoid hemorrhage
BACKGROUND Monitoring of cardiac output (CO) is important for promising safe approach to goal-directed hemodynamic therapy for delayed cerebral ischemia (DCI) after subarachnoid hemorrhage (SAH), but is often precluded by the invasiveness and complexity of ongoing monitoring modalities. We examined the clinical utility of less-invasive management using an uncalibrated arterial pressure waveform...
متن کاملEarly intensive versus minimally invasive approach to postoperative hemodynamic management after subarachnoid hemorrhage.
BACKGROUND AND PURPOSE The results of previous studies suggest that early goal-directed fluid therapy (EGDT) reduces delayed cerebral ischemia (DCI) after aneurysmal subarachnoid hemorrhage, but the effects of EGDT on clinical outcomes are still unclear. This study aimed to determine whether EGDT improves outcomes compared with standard less-invasive hemodynamic therapy. METHODS This study in...
متن کاملAssessing the Left Ventricular Systolic Function at the Bedside: The Role of Transpulmonary Thermodilution-Derived Indices
Evaluating the systolic function of the left ventricle (LV) is important in the hemodynamic management of the critically ill patients with circulatory failure. Echocardiography is considered the standard monitor for estimating the LV function at the bedside in the intensive care unit. However, it requires a trained operator and is not a real-time monitoring tool. For monitoring of the systolic ...
متن کاملImpact of transpulmonary thermodilution-based cardiac contractility and extravascular lung water measurements on clinical outcome of patients with Takotsubo cardiomyopathy after subarachnoid hemorrhage: a retrospective observational study
INTRODUCTION Takotsubo cardiomyopathy (TCM) is a life-threatening systemic consequence early after subarachnoid hemorrhage (SAH), but precise hemodynamics and related outcome have not been studied. The purpose of this study was to investigate the TCM-induced cardiac function by transpulmonary thermodilution and its impact on clinical outcome of SAH. METHODS We retrospectively analyzed 46 cons...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 40 7 شماره
صفحات -
تاریخ انتشار 2009