A new closed-loop control system for isoflurane using bispectral index outperforms manual control.
نویسندگان
چکیده
BACKGROUND Automatic control of depth of hypnosis using the Bispectral Index (BIS) can help to reduce phases of inadequate control. Automated BIS control with propofol or isoflurane administration via an infusion system has recently been described, a comparable study with isoflurane administration via a vaporizer had not been conducted yet. Our hypothesis was that our new model based closed-loop control system can safely be applied clinically and maintains the BIS within a defined target range better than manual control. METHODS Twenty-three patients, American Society of Anesthesiologists risk class I-III, scheduled for decompressive spinal surgery were randomized into groups with either closed-loop or manual control of BIS using isoflurane. An alfentanil target-controlled infusion was adjusted according to standard clinical practice. The BIS target was set to 50 during the operation. The necessity of human intervention in the control system and events of inadequate sedation (BIS <40 or BIS >60) were counted. The number of phases of inadequate control, defined as BIS >/=65 for more than 3 min, were recorded. The performance of the controller was assessed by several indicators (mean absolute deviation and median absolute performance error) and measured during the skin incision phase, the subsequent low flow phase, and the wound closure phase. Recovery profiles of both groups were compared. RESULTS No human intervention was necessary in the closed-loop control group. The occurrence of inadequate BIS was quantified with the mean and median values of the area under the curve and amounted to 0.360 and 0.088 for the manual control group and 0.049 and 0.017 for the closed-loop control group, respectively. In the manual control group nine phases of inadequate control were recorded, compared with one in the closed-loop control group, 10.3% to 0.5% of all observed anesthesia time. During all phases the averages of the performance parameters (mean absolute deviation and median absolute performance error) were more than 30% smaller in closed-loop control than in manual control (P < 0.05 between groups). CONCLUSIONS Closed-loop control with BIS using isoflurane can safely be applied clinically and performs significantly better than manual control, even in phases with abrupt changes of stimulation that cannot be foreseen by the control system.
منابع مشابه
Titration of propofol for anesthetic induction and maintenance guided by the bispectral index: closed-loop versus manual control: a prospective, randomized, multicenter study.
BACKGROUND This report describes a closed-loop titration of propofol target control infusion based on a proportional-differential algorithm guided by the Bispectral Index (BIS) allowing induction and maintenance of general anesthesia and compares this to manual propofol target control infusion. METHODS One hundred sixty-four patients scheduled to undergo elective minor or major surgery were p...
متن کاملRobust Adaptive Control of Hypnosis during Anesthesia
A closed-loop controller for hypnosis was designed and validated on humans at our laboratory. The controller aims at regulating the Bispectral Index (BIS) a surrogate measure of hypnosis derived from the electroencephalogram of the patient with the volatile anesthetic isoflurane administered with a closed-circuit breathing system. The control algorithm consists of a cascaded Internal Model Cont...
متن کاملQUALITY AND PATIENT SAFETY Evaluation of a novel closed-loop total intravenous anaesthesia drug delivery system: a randomized controlled trial
Editor’s key points † Automatic feedback control depends on having a reliable, measurable control variable. † An automatic system for closed-loop administration of i.v. anaesthesia drugs was compared with manual control. † Bispectral index and a compound analgesia score were used as the target controls. † Time within excellent (≤10%) and good (11–20%) range of the two targets was better with th...
متن کاملClosed-loop control of anesthesia using Bispectral index: performance assessment in patients undergoing major orthopedic surgery under combined general and regional anesthesia.
BACKGROUND The Bispectral Index (BIS) is an electroencephalogram-derived measure of anesthetic depth. A closed-loop anesthesia system was built using BIS as the control variable, a proportional-integral-differential control algorithm, and a propofol target-controlled infusion system as the control actuator. Closed-loop performance was assessed in 10 adult patients. METHODS Ten adult patients ...
متن کاملComparison of closed-loop controlled administration of propofol using Bispectral Index as the controlled variable versus "standard practice" controlled administration.
BACKGROUND This report describes a new closed-loop control system for propofol that uses the Bispectral Index (BIS) as the controlled variable in a patient-individualized, adaptive, model-based control system, and compares this system with manually controlled administration of propofol using hemodynamic and somatic changes to guide anesthesia. METHODS Twenty female patients, American Society ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anesthesiology
دوره 101 3 شماره
صفحات -
تاریخ انتشار 2004