Fracture configurations of the equine radius and tibia after a simulated kick.
نویسندگان
چکیده
The objective of this postmortem study was to determine the fracture configurations of the equine radius and tibia after a simulated kick. Fracture configurations of 35 radii and 36 tibiae from 19 adult horses were evaluated after a simulated kick in an experimental ex-vivo study. The bones were dissected, the proximal and distal ends were embedded in resin, fixed horizontally and preloaded in compression, and a steel impactor, designed to simulate a shod equine hoof, was dropped from a height of three to six metres onto the diaphysis. The experiments were filmed with a high-speed camera (30,000 pictures/second). The bones were then photographed and radiographed using a C-arm based 3D imaging device. A software programme (Osirix) was used to reconstruct the fissured and fractured bones three-dimensionally on a computer screen for assessment of the fracture configuration and fissure lines. Incomplete fractures occurred in 26 bones and complete fractures in 42. The complete fractures included 22 butterfly and 20 simple fractures; the latter included 17 oblique, two transverse and one longitudinal fracture. Additional longitudinal fissures occurred in 98% of the fractures. The butterfly fragment was always located on the side opposite the impact. There was a significant correlation between the type of bone and the fracture configuration: butterfly and oblique fractures occurred more frequently in the tibia, and incomplete fractures occurred more frequently in the radius. The data collected can be used to optimize evaluation of fractures and fissures caused by a kick and thereby improve surgical stabilization.
منابع مشابه
The effect of prednisolone on the sensitivity of Technetium 99m-methylene diphosphonate ( 99m Tc-MDP) scintigraphy to detect simulated closed fracture in the rat tibia
Introduction: The purpose of the present study was to evaluate the effect of prednisolone on the sensitivity of bone scanning to detect the simulated closed fracture in the rat tibia. Methods: A total number of forty eight adult, male NMRI rats randomly assigned into two parts, one part for 4 and other for 8 weeks experiments. Each part has been divided into four groups, one group not receivi...
متن کاملEconomic Analysis of Bisphosphonate Use after Distal Radius Fracture for Prevention of Hip Fracture
Background: Osteoporosis is a common condition among the elderly population, and is associated with an increased risk of fracture. One of the most common fragility fractures involve the distal radius, and are associated with risk of subsequent fragility fracture. Early treatment with bisphosphonates has been suggested to decrease the population hip fracture burden. However, there have been no p...
متن کاملAssessment of the treatment outcome of closed extra-articular distal tibia fracture: IM nailing vs plating
Abstract Background: The tibial diaphyseal fractures are the most common type of long bone fractures encountered by most orthopedic surgeons. In accordance with descriptive indices of tibia fractures on the basis of their location in the bone, distal tibia fractures have the second incidence of all tibia fractures after the middle tibia fractures. The purpose of the study was to asses...
متن کاملBiomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing
Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experimen...
متن کاملThe use of combined 3.5 LCP unicortical plate and nail fixation in proximal tibia fractures and prevention of valgus and anterior angulation
Introduction: Intramedullary nailing (IMN) of high tibia fracture has some mechanical and biological advantages over the other form of fixation. However, valgus, apex anterior malalignment and anterior displacement of proximal fragment commonly occur after isolated IMN fixation of proximal high tibia fracture. The purpose of this study is to determine the effectiveness of using 3.5-mm locking c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Veterinary and comparative orthopaedics and traumatology : V.C.O.T
دوره 21 1 شماره
صفحات -
تاریخ انتشار 2008