Carotid Stent Fracture from Stylocarotid Syndrome.

نویسندگان

  • Jeffrey D Hooker
  • David A Joyner
  • Edward P Farley
  • Majid Khan
چکیده

Eagle syndrome is a rare condition resulting from elongation of the temporal styloid process or calcification of its associated stylohyoid ligaments. Although usually presenting with pain or odynophagia, Eagle syndrome has been reported to cause a multitude of neurologic symptoms or vascular complications, some of which can be life-threatening. We present a case in which an endovascularly placed internal carotid artery stent in close proximity to a calcified stylohyoid ligament resulted in stent fracture with subsequent stent and vessel occlusion. We review and discuss the presentation, diagnosis, etiology, complications and treatment options of the syndrome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of vascular laboratory in the management of Eagle syndrome

Eagle syndrome is caused by an elongated styloid process or calcified stylohyoid ligament. The stylocarotid variant with neurologic symptoms is rare and presents a diagnostic challenge. Patients may present with transient ischemic attacks, syncope, or less well defined symptoms like episodic dizziness. We report use of vascular laboratory testing in the management of Eagle syndrome. In one pati...

متن کامل

In-stent stenosis in the patient with internal carotid aneurysm after treated by the Willis covered stent

In-stent stenosis after treated by Willis covered stent-case reports. BACKGROUND Advancements in minimally invasive technology have allowed endovascular reconstruction of internal carotid aneurysm. However, in-stent stenosis is an important and well-characterized complication of stenting after the treatment of internal carotid aneurysm. CASE DESCRIPTION We would present 2 patients who were ...

متن کامل

Late coronary ostial stent fracture and embolism causing an acute thrombotic occlusion of the carotid artery with cerebral infarction.

A 56-year-old woman presented 30 minutes after onset of a right arm paresis. The cardiovascular risk factors included high cholesterol levels and heavy smoking, leading to a posterior myocardial infarction 6 years earlier, with stenting of a subtotal right coronary artery (RCA) ostial stenosis (3×13 mm bare metal stent). A symptomatic 70% RCA ostial restenosis, 9 months after initial percutaneo...

متن کامل

Endoluminal Stent Placement in the Management of Recurrent Carotid Blowout Syndrome

This report is of a patient with acute carotid blowout syndrome that was managed successfully with emergency placement of a covered stent. A 68-year-old man with carcinoma of the tongue had been treated surgically and underwent repeated radiotherapy for recurrence. He presented with intermittent brisk bleeding from a wound in his neck. An urgent carotid angiogram was performed and revealed a ps...

متن کامل

Surgical management for retained distal embolic protection device and fractured guidewire after carotid artery stenting

Entrapment and fracture of carotid angioplasty and stenting hardware is a rare complication of percutaneous stenting procedures. We describe a case of a retained distal filter embolic protection device and guidewire in a 57-year-old male in Beijing, China. After unsuccessful attempts at removal via interventional methods, a second stent was deployed to secure the original hardware in situ, and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of radiology case reports

دوره 10 6  شماره 

صفحات  -

تاریخ انتشار 2016