Distortion Correction in Scanning Transmission Electron Microcopy with Controllable Scanning Pathways
نویسندگان
چکیده
Quantitative intensity and distance measurements in atomically resolved scanning transmission electron microscopy (STEM) imaging relies on the precision of the intensity and position of the images corresponding to the scanned sample area. Conventional STEM rastering modes are limited by drift distortion in the slow scan direction. It has been realized that the scan direction is a parameter that can be tuned to enhance STEM image quality. For example, the revolving STEM (RevSTEM) method utilizes sequential imaging at varying scan directions to effectively eliminate drift distortion from atomic resolution images [1]; however, the scan pattern within each frame is still limited by conventional STEM rastering modes and drift. By controlling the scanning trajectories in an aberration-corrected STEM, Jesse et al. have shown that it is possible to precisely position the probe along a predefined path [2]. An array of intensity data at frequencies up to 2 MHz can be simultaneously acquired and then reconstructed to form an interpretable 2D STEM image. This so-called general-scan STEM (G-STEM) approach opens up new possibilities for STEM imaging and quantitative analysis. For example, using a spiral-scanning path, fly-back can be avoided to save frame acquisition time for fast imaging of beam sensitive materials. This also enables the possibility for compressed sensing with an optimized scan path. However, the G-STEM images show complicated image distortions depending on the scan path that are not fully understood. Figure 1a shows a typical G-STEM spiral-scan path that was selected for equal sampling over the sequential turns of the spiral. Figures 1b and 1c show typical G-STEM annular dark field (ADF)-STEM images acquired from an outward and inward spiral scan across an interface between strontium titanate (STO) and lanthanum strontium manganite (LSMO) acquired at 100kV using a Nion UltraSTEM. The obvious distortion in the center is attributed to hysteresis and phase-lag of the scan system electronics and high velocity within the center during the transition from inward-to-outward spiraling. Here, we propose a distortion correction algorithm that can be applied for any scanning trajectories along a predefined curve with an array of x-y coordinates (xi, yi). Although the curve may fit some analytical functions, the actual movement of the STEM probe follows discrete points. The velocity v(xi, yi) of the probe at point (xi, yi) is calculated as (xi-xi-1, yi-yi-1)/t, where t is inversion of read-out frequency, which is analogous to pixel dwell time in conventional STEM rastering mode. The acceleration a(xi, yi) is defined as (v(xi, yi)v(xi-1, yi-1))/t. The displacement of each probe position from the ideal position can then be compensated as a linear combination of velocity and acceleration using: (dxi, dyi)=Av(xi, yi)+Ba(xi, yi) (1) where A and B are coefficients that can be refined from experimental STEM images. Figures 1d and 1e show the corrected STEM image (with A = -17t and B = 0) where the distortion is essentially removed. To aid in the calibration of scan electronics, a serpentine raster scan was generated such that the scan 900 doi:10.1017/S1431927616005341 Microsc. Microanal. 22 (Suppl 3), 2016 © Microscopy Society of America 2016
منابع مشابه
Attenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]
Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...
متن کاملReview of transmission scanning configurations in cardiac SPECT
The diagnostic accuracy of single photon emission computed tomography (SPECT) is profoundly influenced by attenuation phenomenon. Soft tissue attenuation degrades cardiac SPECT image quality, thereby decreasing the possibility of the detection of the lesions. A variety of correction techniques based on different assumptions have been used to reduce the impact of attenuation. Several types of sy...
متن کاملPrecision controlled atomic resolution scanning transmission electron microscopy using spiral scan pathways
Atomic-resolution imaging in an aberration-corrected scanning transmission electron microscope (STEM) can enable direct correlation between atomic structure and materials functionality. The fast and precise control of the STEM probe is, however, challenging because the true beam location deviates from the assigned location depending on the properties of the deflectors. To reduce these deviation...
متن کاملHierachical Porous Carbon Structures from Cellulose Acetate Fibers
This study describes the transformation of cellulose acetate filters into porous carbon structures by a facile, direct process. Filters from cigarettes were used as the source for cellulose acetate filters. Carbon was obtained by high-temperature treatment under inert conditions without extensive preparative methods. The resulting carbon materials showed structural features on different length ...
متن کاملElectron Irradiation Induced Structural Changes in Nickel Nanorods Encapsulated in Carbon Nanotubes
Nickel nanorods encapsulated inside the multiwalled carbon nanotubes were prepared using microwave plasma chemical vapor deposition (MPCVD) technique. The as prepared tubes were investigated by scanning electron microcopy (SEM), x-ray diffraction (XRD) and high resolution transmission electron microscopy (HRTEM). HRTEM study of these tubes exhibits long, good crystalline nickel filled CNTs with...
متن کامل