Validity of indicator-dilution determinations of cardiac output in patients with mitral regurgitation.

نویسندگان

  • P Samet
  • W H Bernstein
  • C Castillo
چکیده

mHE indicator-dilution method has been widely employed for determination of cardiac output since its introduction by Stewart' and Hamilton and associates.2 The effect of unrecognized recirculation of indicator particles upon the primary indicator time-concentration curve has caused concern as to whether this method may be employed in such conditions as mitral regurgitation3' 4and as to whether the right heart may be employed with validity as an injection site when systemic arterial sampling sites are utilized.5 A previous study from this laboratory has demonstrated that left ventricular cardiac outputs were virtually identical when the pulmonary artery and the left atrium were used as injection sites with sampling from systemic arterial sites.6 The purpose of this report is to examine data as to the effect of mitral regurgitation upon the validity of the indicator-dilution curve for the determination of cardiac output employing right atrial injection and systemic and pulmonary artery sampling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An appraisal of the double indicator-dilution method for the estimation of mitral regurgitation in human subjects.

T HE shape of an indicator-dilution curve is determined by at least 4 variables: cardiac output, the volume between the injection site and the sampling site, the presence of a left-to-right intracardiac shunt, and the presence of valvular regurgitation.1-3 In the absence of an intracardiac shunt and valvular regurgitation, one can predict the downslope of the arterial dilution curve, using the ...

متن کامل

Validity of indicator-dilution determination of cardiac output in patients with aortic regurgitation.

A PREVIOUS STUDY from this laboratory analyzed the effect of mitral regurgita-tion on the validity of the indicator-dilution determination of cardiac output.1 The potential problem of unrecognized early recircula-tion of indicator particles on the primary indicator time-concentration curve2 3 was discussed. The purpose of this report is to extend these observations to patients with aortic regur...

متن کامل

Comparison of left ventricular and pulmonary arterial injection sites in determination of cardiac output by indicator dilution technique.

Cardiac outputs calculated from left ventricular indicator dilution curves were compared to outputs calculated from pulmonary arterial curves in 58 patients with a variety of cardiac abnormalities. Cardiac outputs calculated from left ventricular and pulmonary arterial curves differed by only 0.037 ± 0.052 LI mm. Individual measurements of cardiac output using left ventricular curves had an est...

متن کامل

Calculation of Cardiac Output from Indicator-dilution Curves in the Presence of Mitral Regurgitation.

M EIER and Zierlerl have lucidly presented the theory underlying the application of indicator dilution of the measurement of flow in the vascular bed. This theory is not violated by the presence of valve incompetence provided that indicator particles that recirculate and reenter the vascular system can be excluded from the primary indicator concentration-time curve. Valve incompetence results i...

متن کامل

Indicator-dilution curves during methoxamine infusion n patients with mitral valvular disease.

DURING intravenous infusion of a vasopressor agent (norepinephrine or methoxamine), the "Y" wave of the left atrial pressure or of the pulmonary artery wedge pressure in patients with predominant mitral insufficiency was significantly increased.'This change presumably reflects augmentation of the degree of regurgitation in these patients and is most likely the outcome of an acutely increased sy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 33 3  شماره 

صفحات  -

تاریخ انتشار 1966