Performance evaluation of gas chromatography-atmospheric pressure chemical ionization-time-of-flight mass spectrometry for metabolic fingerprinting and profiling.

نویسندگان

  • Christian J Wachsmuth
  • Martin F Almstetter
  • Magdalena C Waldhier
  • Michael A Gruber
  • Nadine Nürnberger
  • Peter J Oefner
  • Katja Dettmer
چکیده

Gas chromatography-atmospheric-pressure chemical ionization-time-of-flight mass spectrometry (GC-APCI-TOFMS) was compared to GC × GC-electron ionization (EI)-TOFMS, GC-EI-TOFMS, GC-chemical ionization (CI)-quadrupole mass spectrometry (qMS), and GC-EI-qMS in terms of reproducibility, dynamic range, limit of detection, and quantification using a mix of 43 metabolites and 12 stable isotope-labeled standards. Lower limits of quantification for GC-APCI-TOFMS ranged between 0.06 and 7.81 μM, and relative standard deviations for calibration replicates were between 0.4% and 8.7%. For all compounds and techniques, except in four cases, R(2) values were above 0.99. Regarding limits of quantification, GC-APCI-TOFMS was inferior to only GC × GC-EI-TOFMS, but outperformed all other techniques tested. GC-APCI-TOFMS was further applied to the metabolic fingerprinting of two Escherichia coli strains. Of 45 features that differed significantly (false discovery rate < 0.05) between the strains, 25 metabolites were identified through highly accurate and reproducible (Δm ± SD below 5 mDa over m/z 190-722) mass measurements. Starting from the quasimolecular ion, six additional metabolites were identified that had not been found in a previous study using GC × GC-EI-TOFMS and an EI mass spectral library for identification purposes. Silylation adducts formed in the APCI source assisted the identification of unknown compounds, as their formation is structure-dependent and is not observed for compounds lacking a carboxylic group.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chemical derivatization and mass spectral libraries in metabolic profiling by GC/MS and LC/MS/MS.

An overview is presented of gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS), the two major hyphenated techniques employed in metabolic profiling that complement direct 'fingerprinting' methods such as atmospheric pressure ionization (API) quadrupole time-of-flight MS, API Fourier transform MS, and NMR. In GC/MS, the analytes are normally derivati...

متن کامل

Integration of ion-exchange chromatography fractionation with reversed-phase liquid chromatography-atmospheric pressure chemical ionization mass spectrometer and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for isolation and identification of compounds in Psoralea corylifolia.

An approach for the separation and identification of components in a traditional Chinese medicine Psoralea corylifolia was developed. Ion-exchange chromatography (IEC) was applied for the fractionation of P. corylifolia extract, and then followed by concentration of all the fractions with rotary vacuum evaporator. Each of the enriched fractions was then further separated on an ODS column with d...

متن کامل

Effective evaluation of catalytic deoxygenation for in situ catalytic fast pyrolysis using gas chromatography–high resolution mass spectrometry

Effective deoxygenation in catalytic fast pyrolysis (CFP) is crucial for bio-oil stabilization and its successful commercialization. Herein, we utilize a new analytical platform that couples gas chromatography (GC) to dopant-assisted atmospheric pressure chemical ionization (dAPCI) time-of-flight mass spectrometry (TOF MS) to evaluate catalytic deoxygenation of cellulose pyrolysis. Soft ionizat...

متن کامل

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

Liquid Chromatography-Mass Spectrometry in Studies of Drug Metabolism and Permeability

Poor pharmacokinetics is one of the reasons for the withdrawal of drug candidates from clinical trials. There is an urgent need for investigating in vitro ADME (absorption, distribution, metabolism and excretion) properties and recognising unsuitable drug candidates as early as possible in the drug development process. Current throughput of in vitro ADME profiling is insufficient because effect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 83 19  شماره 

صفحات  -

تاریخ انتشار 2011