Does a deep seated L5 vertebra position with respect to the iliac crests affect the accuracy of percutaneous pedicle screw placement at lumbosacral junction?

نویسندگان

  • Jing Guo
  • Lianjin Guo
  • Juzhou Gao
  • Qinjie Ling
  • Zhixun Yin
  • Erxing He
چکیده

BACKGROUND Significant prominence of iliac crests with a deep seated L5 vertebra can potentially interfere with the screw trajectory when placing percutaneous pedicle screws (PPS) at the lumbosacral segment. The objective of this study was to investigate the influence of L5 position in relation to the iliac crests on the accuracy of percutaneous placement of lumbosacral pedicle screws. METHODS From Oct 2012 to Sep 2014, 54 patients who underwent PPS placement at L5-S1 segment were recruited. Patients were divided into 2 groups: the L5-Seated Group (L5-S Group, n = 34) including patients with intercrest lines passing through the L4 vertebra or L4/5 intervertebral disc; whereas the L5-Non-Seated Group (L5-NS Group, n = 20) including patients with intercrest lines passing through the L5 vertebra. Postoperative computerized tomography was obtained in all patients, and PPS accuracy was evaluated by grading pedicle breach (Grade 0, no breach; Grade 1, ≤2mm; Grade 2, >2mm without neurological compromise; Grade 3, with complications). Screw convergence angle (SCA), defined as the angle subtended by the screw axis and vertebral midline, was also recorded. RESULTS In the L5-S Group, 82.4% (56/68) screws were measured as Grade 0 at L5, and 66.2% (45/68) were Grade 0 at S1; meanwhile, in the L5-NS Group, 77.5% (31/40) and 75.0% (30/40) screws were Grade 0 at L5 and S1, respectively. Misplacement rate was numerically higher at S1 in the L5-S Group (P > 0.05). There were significantly more medial pedicle violations at S1 in the L5-S Group as compared to the L5-NS Group (25.0% vs 7.5%, P = 0.024). No statistical difference was found in L5 SCA between the 2 groups (L5-S Group 23.7° ± 7.4° vs L5-NS Group 23.4° ± 10.6°, P = 0.945); however, S1 SCA was significantly smaller in the L5-S Group (14.7° ± 5.8°) when compared with the L5-NS Group (20.8° ± 5.2°) (P = 0.036). CONCLUSIONS A deep seated L5 vertebra with respect to the iliac crests might compromise the accuracy of PPS placement at S1 vertebra. Severe iliac prominence may interfere with the screw trajectory and limit the medial angulation of pedicle screw for percutaneous S1 fixation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Percutaneous Lumbosacral Pedicle Screw Placement Using the Oblique Fluoroscopic View Based on Computed Tomography Evaluations

STUDY DESIGN Retrospective. PURPOSE This study aims to investigate the accuracy of the oblique fluoroscopic view, based on preoperative computed tomography (CT) images for accurate placement of lumbosacral percutaneous pedicle screws (PPS). OVERVIEW OF LITERATURE Although PPS misplacement has been reported as one of the main complications in minimally invasive spine surgery, there is no com...

متن کامل

Rigid Posterior Lumbopelvic Fixation without Formal Debridement for Pyogenic Vertebral Diskitis and Osteomyelitis Involving the Lumbosacral Junction: Technical Report

BACKGROUND Pelvic fixation with S2-alar-iliac (S2AI) screws can increase the rigidity of a lumbosacral construct, which may promote bone healing, improve antibiotic delivery to infected tissues, and avoid L5-S1 pseudarthrosis. PURPOSE To describe the use of single-stage posterior fixation without debridement for the treatment of pyogenic vertebral diskitis and osteomyelitis (PVDO) at the lumb...

متن کامل

Electromagnetic Navigation in Minimally Invasive Spine Surgery: Results of a Cadaveric Study to Evaluate Percutaneous Pedicle Screw Insertion

BACKGROUND This cadaveric study compared efficacy and safety of an electromagnetic (EM) guidance system versus conventional fluoroscopy for percutaneous pedicle screw fixation. As percutaneous pedicle screw fixation becomes increasingly common in spinal surgery, intraoperative imaging systems that maximize efficiency while minimizing radiation exposure and inaccurate trajectories will be progre...

متن کامل

Percutaneous pedicle screw reduction and axial presacral lumbar interbody fusion for treatment of lumbosacral spondylolisthesis: A case series

INTRODUCTION Traditional surgical management of lumbosacral spondylolisthesis is technically challenging and is associated with significant complications. The advent of minimally invasive surgical techniques offers patients treatment alternatives with lower operative morbidity risk. The combination of percutaneous pedicle screw reduction and an axial presacral approach for lumbosacral discectom...

متن کامل

Evaluation of the relationship between L5-S1 spondylolysis and isthmic spondylolisthesis and lumbosacral-pelvic morphology by imaging via 2- and 3-dimensional reformatted computed tomography.

PURPOSE The purpose of this study was to investigate the differences in the axial and coronal parameters of lumbosacropelvic morphology among a population with spondylolysis and healthy individuals by using 2- and 3-dimensional (3D) reformatted computed tomographic images. Moreover, this study aimed to evaluate the differences in sagittal geometry. MATERIALS AND METHODS The stone protocol abd...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017