Selection of the optimal nonexercise stress for the evaluation of ischemic regional myocardial dysfunction and malperfusion. Comparison of dobutamine and adenosine using echocardiography and 99mTc-MIBI single photon emission computed tomography.

نویسندگان

  • T Marwick
  • B Willemart
  • A M D'Hondt
  • T Baudhuin
  • W Wijns
  • J M Detry
  • J Melin
چکیده

BACKGROUND The mechanisms of action of exercise-simulating and vasodilator stressors support their combination with imaging techniques that evaluate left ventricular function and perfusion, respectively. However, reported accuracies of either pharmacological stress together with two-dimensional echocardiography (2DE) or single photon emission computed tomography (SPECT) of myocardial perfusion are similar. The purpose of this study was to establish the optimal stress for each imaging technique by comparing the results of digitized 2DE and 99mTc-methoxyisobutyl isonitrile (MIBI) SPECT using both dobutamine and adenosine stresses in the same patients and conditions. METHODS AND RESULTS Ninety-seven consecutive patients without evidence of previous infarction undergoing coronary angiography for clinical indications were studied prospectively. Dobutamine was infused during clinical, ECG, and echocardiographic monitoring in dose increments from 5 to 40 micrograms.kg-1.min-1. Adenosine was infused under the same conditions in doses of 0.10, 0.14, and 0.18 mg.kg-1.min-1. For each protocol, the end points were achievement of peak dose, development of severe ischemia, or intolerable side effects. At peak stress, 20 mCi of MIBI was injected, and SPECT imaging was performed 2 hours later; abnormal poststress images were compared with resting SPECT: Digitized 2DE images were compared qualitatively before, during, and after stress in a cine-loop display. Significant coronary disease (n = 59 patients) was defined by the quantification of > 50% stenosis in a major epicardial vessel. The sensitivity of adenosine 2DE was 58%, less than those of adenosine MIBI (86%, p = 0.001), dobutamine 2DE (85%, p = 0.001), and dobutamine MIBI (80%, p = 0.01). Their respective specificities were 87%, 71%, 82%, and 74% (p = NS). The accuracy of adenosine 2DE was 69%, compared with 80% for adenosine MIBI (p < 0.001), 84% for dobutamine 2DE (p = 0.001), and 77% for dobutamine MIBI (p = 0.005); the latter three did not differ significantly in either sensitivity or accuracy. CONCLUSIONS This prospective, direct comparison of alternative pharmacological stresses in patients without myocardial infarction shows vasodilator stress scintigraphy and dobutamine stress echocardiography and scintigraphy to share equivalent levels of sensitivity. All three are significantly more sensitive than adenosine stress echocardiography. Dobutamine stress may be used for wall motion or perfusion imaging, but adenosine stress is best combined with perfusion scintigraphy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selection of the Optimal Nonexercise Stress for the Evaluation of Ischemic Regional Myocardial Dysfunction and Malperfusion

Background. The mechanisms of action of exercise-simulating and vasodilator stressors support their combination with imaging techniques that evaluate left ventricular function and perfusion, respectively. However, reported accuracies of either pharmacological stress together with two-dimensional echocardiography (2DE) or single photon emission computed tomography (SPECT) of myocardial perfusion...

متن کامل

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Noninvasive diagnosis of coronary artery stenosis in women with limited exercise capacity: comparison of dobutamine stress echocardiography and 99mTc sestamibi single-photon emission CT.

OBJECTIVES To compare the accuracy of dobutamine stress echocardiography (DSE) and simultaneous 99mTc sestamibi (MIBI) single-photon emission CT (SPECT) imaging for the diagnosis of coronary artery stenosis in women. PATIENTS Seventy women with limited exercise capacity referred for evaluation of myocardial ischemia. METHODS DSE (up to 40 microg/kg/min) was performed in conjunction with str...

متن کامل

Comparison of glucose-insulin-thallium-201 infusion single photon emission computed tomography (SPECT), stress-redistribution-reinjection thallium-201 SPECT and low dose dobutamine echocardiography for prediction of reversible dysfunction.

The usefulness of glucose-insulin-thallium-201 (GI-Tl) infusion single photon emission computed tomography (SPECT) in predicting reversible dysfunction has not been evaluated, so the present study recruited 20 patients with regional ischemic dysfunction for investigation. All patients underwent GI-Tl SPECT, post-stress Tl reinjection imaging and low dose dobutamine echocardiography. The diagnos...

متن کامل

Contrast Echocardiography: A New Method for the Assesment of Myocardial Perfusion in Coronary Artery Disease

highly suited to the non-invasive assessment of myocardial function. Changes in myocardial perfusion can be depicted by echocardiography indirectly as wall motion and thickening abnormalities. Regional left ventricular systolic function estimation is useful in the detection of ischemic but viable myocardium and provides information of paramount importance concerning the management of patients w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 87 2  شماره 

صفحات  -

تاریخ انتشار 1993