Application of the Böhm chamber for reference beta dose measurements and the calibration of personal dosimeters

نویسنده

  • Krystian Skubacz
چکیده

The appropriate evaluation of measured doses in mixed fi elds requires the calibration of dosimeters in relation to different types of radiation and exposure conditions in order to split the signal into individual components corresponding to the specifi c radiation and exposure conditions of the entire period and evaluate the critical level, lower limit of detection and corresponding uncertainty [1]. The Panasonic UD-813 thermoluminescent dosimeters (TLDs) are used to evaluate mainly the doses related to neutrons but their design is appropriate for their use in the mixed fi eld. Therefore, the dosimeters have to be irradiated to fulfi l these tasks by beta, gamma, neutron and X-ray using the slab phantom or free in the air for environmental dosimetry. The 137Cs gamma sources and 137Sr beta sources that were used to fulfi l the task were mounted on the IM6/M-2 and IB1/P installation, respectively, and the X-ray that could be modifi ed by fi lters recommended by the ISO standard 4037-1:1996 [2] was generated by the XCS-320-ST/X-RAY CAL (320 kV) device. All of these installations, made by TEMA Application of the Böhm chamber for reference beta dose measurements and the calibration of personal dosimeters Krystian Skubacz

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Evaluation of Linac Photon Small Fields using MAGIC Polymer Gels

Introduction: In radiotherapy, methods of treatment planning are becoming increasingly more complicated. This requires verification of the doses delivered to increasingly smaller and more precise regions. Radiotherapy techniques are continuously employing smaller and smaller field sizes to deliver tighter radiation doses with higher therapeutic ratios, generating interest among researchers to p...

متن کامل

Evaluation of Effective Sources in Uncertainty Measurements of Personal Dosimetry by a Harshaw TLD System

Background: The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance.Objective: In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD.Method: T...

متن کامل

Measurement of outdoor and indoor ambient gamma dose rate in Gorgan and Bandar-Torkman cities using gas and thermoluminescent dosimeters

Background and Objective: Human external exposure to natural radiation sources is much more than artificial radiation sources. In this study, external annual effective doses were estimated in cities of Gorgan and Bandar-Torkman by determining ambient gamma dose rate in indoor and outdoor spaces. Materials and Methods: Using an ionization chamber detector, the outdoor and indoor ambient gamma d...

متن کامل

Design and fabrication of cylindrical ionization chamber for application in radiation protection

According to International Atomic Energy Agency (IAEA) recommendations, the calibration of ionization chambers used for radiotherapy dosimetry follows the substitution method which demands the use of a reference ionization chamber. This work introduces the Design and fabrication of cylindrical ionization chamber for dosimetry to be used by standard dosimetry laboratories. The result of the qual...

متن کامل

Calibration and optimization of a low cost diffusion chamber for passive separated measurements of radon and thoron in soil by Lexan PC SSNTD

Background: Separate radon and thoron measurements in soil are very important in assessment of internal exposure due to inhalation of such radioactive gases. Materials and Methods: In this study, a low cost, small size, passive diffusion chamber has been developed for simple measurement of Radon-222 and Radon-220(Thoron) gases separately in soil. The diffusion chamber consists of two films and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016