Agreement between glucose trends derived from three simultaneously worn continuous glucose sensors.
نویسندگان
چکیده
BACKGROUND Sensors detect the rate and direction of glucose trend. They need to be accurate and reproducible as could be evidenced by strong agreement between multiple sensors. We evaluated this relationship through simultaneously worn glucose sensors using several methods of slope analysis. METHODS Ten type 1 diabetic, insulin pump-treated subjects were studied while simultaneously wearing three CGMS Gold sensors each. Sensors were placed in the right abdomen (reference), left abdomen, and left upper arm. Sensors were calibrated and chronologically aligned. Data were only interpreted and included if there were 24 hours of data simultaneously obtained from all three sensors. RESULTS Using a two-point derived slope, increasing the duration of the trend from 5 to 60 minutes improved agreement between sensors. Using a 20-minute rolling average trend (using every 5-minute glucose value during the 20 minutes) improved the agreement to 94.3%. Finally, using whichever of the two comparator sensor rolling average trends was closest to the reference (better of two), the agreement improved to 98.2%. However, for these trend analysis methods, when the absolute reference rate of change was more than 1 mg/dl/min, the agreement decreased. Even with the best analysis approach, at an absolute reference sensor rate of change of >2 mg/dl/min, the agreement between sensors was only 40.0%. CONCLUSION Despite several methods of analysis, trend agreement from multiple sensors diminishes as the absolute rate of change of reference glucose increases.
منابع مشابه
Effect of Lipohypertrophy on Accuracy of Continuous Glucose Monitoring in Patients With Type 1 Diabetes
Repeated delivery of insulin in the same location induces a local reaction in the subcutaneous adipose tissue, often leading to lipohypertrophy (1,2). Advanced lipohypertrophy leads to slower, erratic insulin absorption due to the fibrous, relatively avascular nature of the tissue (3). Although lipohypertrophied tissue is commonly used for continuous glucose monitoring (CGM) sensor sites, the e...
متن کاملReproducibility of glucose measurements using the glucose sensor.
OBJECTIVE Recent studies have confirmed that improved glycemic control decreases the risk of diabetic complications in type 1 and type 2 diabetic patients. The Minimed glucose sensor allows continuous 72-h glucose monitoring and represents a potentially important tool to improve diabetes management. Its use is currently limited to the health care team. Our aim was to evaluate the reproducibilit...
متن کاملA Comparative Effectiveness Analysis of Three Continuous Glucose Monitors
OBJECTIVE To compare three continuous glucose monitoring (CGM) devices in subjects with type 1 diabetes under closed-loop blood glucose (BG) control. RESEARCH DESIGN AND METHODS Six subjects with type 1 diabetes (age 52 ± 14 years, diabetes duration 32 ± 14 years) each participated in two 51-h closed-loop BG control experiments in the hospital. Venous plasma glucose (PG) measurements (GlucoSc...
متن کاملAccuracy of the continuous glucose monitoring system in inpatient and outpatient conditions.
OBJECTIVE To evaluate in inpatient and outpatient conditions, using only non-calibration data, the accuracy of the Continuous Glucose Monitoring System (CG-MS). RESEARCH DESIGN AND METHODS Twelve, 21 and 20 type 1 diabetic patients participated in 3- day inhospital, 6-day ambulatory (i.e., 2 sensors worn consecutively) and 3-day ambulatory studies. Capillary glucose tests (7-8/day) served as ...
متن کاملFeasibility of continuous long-term glucose monitoring from a subcutaneous glucose sensor in humans.
The feasibility of continuous long-term glucose monitoring in humans has not yet been demonstrated. Enzyme-based electrochemical glucose sensors with telemetric output were subcutaneously implanted and evaluated in five human subjects with type I diabetes. Subject-worn radio-receiver data-loggers stored sensor outputs. Every 1-4 weeks the subject's glucose levels were manipulated through the fu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of diabetes science and technology
دوره 2 5 شماره
صفحات -
تاریخ انتشار 2008